Meridian Audio FPP-50HD20, FPP-42HD20, FPP-61HD20 To avoid damage and prolong operating life

Page 3

To avoid damage and prolong operating life:

1.Use only with120V50/60HzAC power.

Continued operation at line voltages greater than 120 Volts AC will shorten the life of the unit, and might even cause a fire hazard.

2.Handle the unit carefully when installing it and do not drop.

3.Set the unit away from heat, excessive dust, and direct sunlight.

4.Protect the inside of the unit from liquids and small metal objects. In case of accident, unplug the power cord and have it serviced by an authorized Service Center.

5.Do not hit or scratch the panel surface as this causes flaws on the surface of the screen.

6.For correct installation and mounting it is strongly recommended to use a trained, authorized dealer.

7.As is the case with any phosphor-based display (like a CRT monitor, for example) light output will gradually decrease over the life of a Plasma Display Panel.

8.To avoid sulfurization it is strongly recommended not to place the unit in a dressing room in a public bath or hot spring bath.

Plasma monitor cleaning procedure:

1.Use a soft dry cloth to clean the front panel and bezel area. Never use solvents such as alcohol or thinner to clean these surfaces.

2.Clean plasma ventilation areas with a vacuum cleaner with a soft brush nozzle attachment.

3.To ensure proper ventilation, cleaning of the ventilation areas must be carried out monthly. More frequent cleaning may be necessary depending on the environment in which the plasma monitor is installed.

Recommendations to avoid or minimize phosphor burn-in:

Like all phosphor-based display devices and all other gas plasma displays, plasma monitors can be susceptible to phosphor burn under certain circumstances. Certain operating conditions, such as the continuous display of a static image over a prolonged period of time, can result in phosphor burn if proper precautions are not taken. To protect your investment in this plasma monitor, please adhere to the following guidelines and recommendations for minimizing the occurrence of image burn:

*Always enable and use your computer’s screen saver function during use with a computer input source.

*Display a moving image whenever possible.

*Change the position of the menu display from time to time.

*Always power down the monitor when you are finished using it.

If the plasma monitor is in long term use or continuous operation take the following measures to reduce the likelihood of phosphor burn:

*Lower the Brightness and Contrast levels as much as possible without impairing image readability.

*Display an image with many colors and color gradations (i.e. photographic or photo-realistic images).

*Create image content with minimal contrast between light and dark areas, for example white characters on black backgrounds. Use complementary or pastel color whenever possible.

*Avoid displaying images with few colors and distinct, sharply defined borders between colors.

* Note: Burn-in is not covered by the warranty.

Contact your dealer for other recommended procedures that will best suit your particular application needs.

Image 3
Contents Digital Cinema Series Precautions Important InformationRisk of Electric Shock Do not Open Recommendations to avoid or minimize phosphor burn-in Use only with120V50/60HzAC powerPlasma monitor cleaning procedure To avoid damage and prolong operating lifeRecommandations importantes PrécautionsMises en garde et précautions de sécurité Méthode de nettoyage du moniteur à plasma Contents Ventilation Requirements for enclosure mounting How to Attach Options to the Plasma MonitorFront View Turns the monitor’s power on and offReceives the signals from the remote control Part Names and FunctionRGB2 Rear View/ Terminal BoardRemote Control Clears the number set by the ID Select button Battery Installation and ReplacementTransmits the remote control signals Not functional for the models covered in this manualUsing the wired remote control mode Handling the remote controlOperating Range Installation Connections Signal Analog Pin Assignments and Signal Levels for 15 pin RGB AnalogBasic Operations To check the remaining time To set the off timerTo cancel the off timer After the power is turned off with the off timerWide Operations When viewing videos or digital video discs Picture Size setting Wide Screen Operation with Computer SignalsWhen Picture Size is set to OFF  Supported resolutionMenu Operations  Advanced menu modeMenu Tree ResetOPTION2 PWR. MGT  Adjusting for the video processor Picture Settings MenuAdjusting the picture  Picture adjustment screenSetting the color temperature Adjusting the color to the desired levelReducing noise in the picture  LOW Tone settings Making the Low Tone adjustments Adjusting the white balance  Gamma settings Audio settings menu Audio Settings MenuAdjusting the colors  Color Tune settingsExample Setting Audio INPUT1 to Video Image Adjust Settings MenuSetting the allocation of the audio connectors Adjusting the Position, Size, Fine Picture, Picture AdjSetting the on-screen menu Option1 Settings Menu OSM Orbiter settings Setting the BNC connectorsChecking the signal being transmitted to RGB1 terminal Setting a computer image to the correct RGB select screen RGB Select modes Setting high definition images to the suitable screen sizeSetting the Input Skip  Input Skip settingsOption2 Settings Menu Resetting to the default valuesSetting the power management for computer images Reducing burn-in of the screen POWER/STANDBY indicatorSetting the picture to suit the movie  PLE settings Orbiter settings  Orbiter Function settings Inverse Settings  Setting the time  To select on for the Working TimeScreen Wiper Speed Setting the screen size for S1/S2 video input Soft Focus settings  Gray Level settings PLUG/PLAY settings Setting the picture size for RGB input signalsSetting the signal and black level for DVI signal  S1/S2 settingsPresent Time Option3 Settings MenuUsing the timer  Present Time settings Special characters in the Program Timer screen Setting the power on mode To reset the program  To reset the data IR Remote settings Enabling/disabling remote control wireless transmission PWR. on Mode settings  Control Lock settingsID number setting Loop Out settingDivider Video Wall setting Divider settings  Video Wall Position settings Auto ID settings  DISP. Mode settings Image Adjust settings PLE Link On Delay Power on delay P. on Delay settings  PLE Link settings Repeat Timer settings Advanced OSM Settings MenuSetting the menu mode Repeat TimerSetting the video signal format Language Settings MenuColor System Settings Menu Setting the language for the menusCommunication Parameters External ControlApplication ConnectionsSymptom Checks Remedy TroubleshootingPage Telephone 408 735 Faroudja Palomar Ave Sunnyvale, CA Limited Warranty Plasma MonitorsThis warranty may be enforced only by the first purchaser For More Information