Meridian Audio FPP-61HD20 POWER/STANDBY indicator, Setting the picture to suit the movie

Page 32

POWER/STANDBY indicator

Power

POWER/

Power

Description

Turning the picture

management

STANDBY

management

 

back on

mode

indicator

operating status

 

 

 

 

 

 

 

On

Green

Not activated.

Horizontal and vertical

Picture already on.

 

 

 

synchronizing signals

 

 

 

 

are present from the

 

 

 

 

computer.

 

 

 

 

 

 

Off

Red

Activated.

Horizontal and/or

Operate the keyboard or

 

 

 

vertical synchronizing

mouse. The picture

 

 

 

signals are not sent

reappears.

 

 

 

from the computer.

 

 

 

 

 

 

Setting the picture to suit the movie

The film image is automatically discriminated and projected in an image mode suited to the picture. [NTSC, PAL, PAL60, 480I (60Hz), 525I (60Hz), 576I (50Hz), 625I (50Hz), 1035I (60Hz), 1080I (60Hz) only]

Example: Setting the “CINEMA MODE” to “OFF”

Set “ADVANCED OSM” to “ON” in the main menu (1/ 2), then perform the following operations.

1.On the MAIN MENU, select “OPTION2”, then press the MENU/ENTER button.

The “OPTION2” screen appears.

2.Use the and buttons to select “CINEMA MODE”.

3.To set the CINEMA MODE to “OFF” ...

Use the  and  buttons to select “OFF”.

The mode switches as follows each time the  or  button is pressed:

ON Χ OFF

 

 

 

OPTION2

 

2 / 3

 

 

PREVIOUS PAGE

 

 

 

POWER MGT.

 

:

OFF

 

CINEMA MODE

 

:

OFF

 

 

 

 

 

 

LONG LIFE

 

 

 

 

GRAY LEVEL

 

:

3

 

S1/S2

 

:

OFF

 

 

NEXT PAGE

 

 

 

 

 

 

SEL.

ADJ.

 

EXIT

RETURN

Information

CINEMA MODE

ON

Automatic discrimination of the

 

image and projection in cinema mode.

OFF

Cinema mode does not function.

Restoring the factory default settings

Select “ALL RESET” under the OPTION1 menu. Note that this also restores other settings to the factory defaults.

Reducing burn-in of the screen

The brightness of the screen, the position of the picture, positive/negative mode and screen wiper are adjusted to reduce burn-in of the screen.

Set “ADVANCED OSM” to “ON” in the main menu (1/ 2), then perform the following operations.

1.On the MAIN MENU, select “OPTION2”, then press the MENU/ENTER button.

The “OPTION2” screen appears.

2.Use the and buttons to select “LONG LIFE”, then press the MENU/ENTER button.

The “LONG LIFE” screen appears.

 

 

 

 

LONG LIFE

 

 

 

PLE

 

:

AUTO

 

 

 

:

OFF

ORBITER

INVERSE

:

OFF

SCREEN WIPER

:

OFF

SOFT FOCUS

:

OFF

 

 

SEL.

ADJ.

 

RETURN

 

 

EXIT

3.Set the LONG LIFE mode using ▲▼ and  buttons. See page 27 to set PLE.

See page 28 to set ORBITER. See page 28 to set INVERSE.

See page 29 to set SCREEN WIPER. See page 30 to set SOFT FOCUS.

Information

Restoring the factory default settings

Select “ALL RESET” under the OPTION1 menu. Note that this also restores other settings to the factory defaults.

PLE (Peak Luminance Enhancement)

Use this to activate the brightness limiter.

Example: Setting “PLE” to “LOCK1”

Perform Steps 1-2 of LONG LIFE, then...

3.Use the and buttons to select “PLE”.

4.Use the  and  buttons to select “LOCK1”.

The mode switches as follows each time the  or  button is pressed:

ΑAUTO Χ LOCK1 Χ LOCK2 Χ LOCK3

 

 

 

 

LONG LIFE

 

 

 

PLE

 

:

LOCK1

 

 

 

 

 

 

ORBITER

:

OFF

INVERSE

:

OFF

SCREEN WIPER

:

OFF

SOFT FOCUS

:

OFF

 

 

SEL.

ADJ.

 

RETURN

 

 

EXIT

26

Information

PLE settings

AUTO .............. The brightness of the screen is

adjusted automatically to suit the picture quality.

Image 32
Contents Digital Cinema Series Risk of Electric Shock Do not Open PrecautionsImportant Information Use only with120V50/60HzAC power Plasma monitor cleaning procedureTo avoid damage and prolong operating life Recommendations to avoid or minimize phosphor burn-inMises en garde et précautions de sécurité Recommandations importantesPrécautions Méthode de nettoyage du moniteur à plasma Contents How to Attach Options to the Plasma Monitor Ventilation Requirements for enclosure mountingTurns the monitor’s power on and off Receives the signals from the remote controlPart Names and Function Front ViewRear View/ Terminal Board RGB2Remote Control Battery Installation and Replacement Transmits the remote control signalsNot functional for the models covered in this manual Clears the number set by the ID Select buttonOperating Range Using the wired remote control modeHandling the remote control Installation Connections Pin Assignments and Signal Levels for 15 pin RGB Analog Signal AnalogBasic Operations To set the off timer To cancel the off timerAfter the power is turned off with the off timer To check the remaining timeWhen viewing videos or digital video discs Wide OperationsWide Screen Operation with Computer Signals When Picture Size is set to OFF Supported resolution  Picture Size setting Advanced menu mode Menu OperationsReset Menu TreeOPTION2 PWR. MGT Picture Settings Menu Adjusting the picture Picture adjustment screen  Adjusting for the video processorReducing noise in the picture Setting the color temperatureAdjusting the color to the desired level Making the Low Tone adjustments  Adjusting the white balance Gamma settings  LOW Tone settingsAudio Settings Menu Adjusting the colors Color Tune settings  Audio settings menuImage Adjust Settings Menu Setting the allocation of the audio connectorsAdjusting the Position, Size, Fine Picture, Picture Adj Example Setting Audio INPUT1 to VideoOption1 Settings Menu Setting the on-screen menuSetting the BNC connectors Checking the signal being transmitted to RGB1 terminalSetting a computer image to the correct RGB select screen  OSM Orbiter settingsSetting high definition images to the suitable screen size Setting the Input Skip Input Skip settings  RGB Select modesSetting the power management for computer images Option2 Settings MenuResetting to the default values POWER/STANDBY indicator Setting the picture to suit the movie PLE settings Reducing burn-in of the screen Inverse Settings  Orbiter settings Orbiter Function settings Screen Wiper  Setting the time To select on for the Working Time Setting the screen size for S1/S2 video input  Soft Focus settings Gray Level settings SpeedSetting the picture size for RGB input signals Setting the signal and black level for DVI signal S1/S2 settings  PLUG/PLAY settingsOption3 Settings Menu Using the timer Present Time settings Present TimeSetting the power on mode  To reset the program To reset the data  Special characters in the Program Timer screenEnabling/disabling remote control wireless transmission  PWR. on Mode settings Control Lock settings  IR Remote settingsLoop Out setting ID number settingVideo Wall setting  Divider settings Video Wall Position settings Divider Image Adjust settings  Auto ID settings DISP. Mode settings On Delay Power on delay  P. on Delay settings PLE Link settings PLE LinkAdvanced OSM Settings Menu Setting the menu modeRepeat Timer  Repeat Timer settingsLanguage Settings Menu Color System Settings MenuSetting the language for the menus Setting the video signal formatExternal Control ApplicationConnections Communication ParametersTroubleshooting Symptom Checks RemedyPage Limited Warranty Plasma Monitors This warranty may be enforced only by the first purchaserFor More Information Telephone 408 735 Faroudja Palomar Ave Sunnyvale, CA