OPERATION
Stopping the Engine
1.Move the throttle to the mid throttle position.
2.Move the steering controls outward.
3.Disengage the mower deck by pressing the blade switch down.
4.When the machine is standing still, activate the park brake by pushing the lever release button and pulling the lever upward.
If the engine has been worked hard, allow it to idle at least 60 seconds to attain a normal operating temperature before stopping. To prevent fouling the spark plugs, avoid idling the engine for longer periods.
Disengage the mower deck and move throttle to minimum
Raise the mower deck
5.Press and release the S/S button to stop the engine. The ignition system will return to the a
The electrical system will automatically shut down thirty seconds after the operator leaves the seat. It can be deactivated immediately by pressing and holding button 1 and button 3 simultaneously for two seconds.
Unexpected Engine Stoppage |
| |
If the engine stops unexpectedly and all of the |
| |
SmartSwitch indicator lights flash simultaneously, |
| |
it is an indication of a nonsafety related shutdown |
| |
(example, running out of gas). The system will reset |
| |
after a few moments and return to a prestart status. | ||
The reason for the shutdown must be identified and | ||
Press the S/S button to stop the engine | ||
corrected prior to attempting a restart (example, refuel |
| |
the unit). |
|