7. GARDEN EXAMPLE
Proposals for installation and settings
Area: 500 m2. There are several islands. No guide wire is necessary. The mower’s default settings do not need to be changed.
Timer: Operating time of 7 hours per day.
Exit angles: One sector 90°- 270°.
Search method: Irregular.
Delay: Guide 1 7 minutes, Guide 2 7 minutes and boundary wire 11 minutes.
Corridor width: 6.
Area: 1,000 m2. There is one small island. Guide wire recommended through the passage.
Timer: Operating time of 14 hours per day.
Exit angles: One sector
Follow loop out: Direction Guide 1, Distance 20 m and Proportion 25 %.
Search method: Irregular, Follow guide wire in and Follow boundary wire in.
Delay: Guide 1 7 minutes, Guide 2 7 minutes and boundary wire 11 minutes.
Corridor width: Guide 1 6, boundary wire 20.
This example only applies to 230 ACX.
Area: 2200 m2. Two guide wires are recommended.
Timer: Operating time of 24 hours per day.
Exit angles: One sector
Follow loop out: Area 1; Direction Guide 1, Distance 30 m and Proportion 15 %. Area 2; Direction Guide 2, Distance 30 m and Proportion 30 %.
Search method: Irregular, Follow guide wire in and Follow boundary wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes and boundary wire 11 minutes.
Corridor width: Guide 1 4, Guide 2 4and boundary wire 6.
66 - English