6. MENU FUNCTIONS
Up to five remote areas can be activated: Area 1, Area 2, Area 3, Area 4 and Area 5 (only three areas on 220 AC). Three values need to be stated to activate an area:
•Direction
Specify to the right, left, guide 1 or guide 2 depending on which direction the area lies from the charging station. The direction is set looking from the charging station in the approach direction of the mower.
When a guide wire is installed the direction can be specified as the guide wire. The mower will now follow the selected guide wire instead of the boundary wire, (only guide 1 is available on 220 AC).
•Distance
Specify the number of metres along the boundary wire or guide wire from the charging station to the place in the remote area where the mower shall start mowing.
Tip! Use the Test OUT
•Proportion
Specify a value for how often of the occasions Automower leaves the charging station it should follow the loop out to the remote area.
For example the value 20 % means that in 20 % of the occasions Automower leaves the charging station, it does it in the direction to the remote area. In the remaining 80 % of the occasions the mower leaves the charging station according to the setting made for its function Exit angles
If a value of 20 % is specified for Area 1 and
10 % for Area 2, the remaining 70 % is allocated to the selection under Exit angles
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
Area 1
Area 2
Area 3
Area 4
Area 5
Direction
Distance
Proportion
Area 1
Area 2
Area 3
Area 4
Area 5
Direction
Distance
Proportion
Right
Left
Guide 1
Guide 2
English - 53