1. Manuals
  2. Brands
  3. Home Audio
  4. Soundbar/SoundTower
  5. Samsung
  6. Home Audio
  7. Soundbar/SoundTower

Samsung SHR-6164P CONNECTING THE RS-485DEVICE, 22_ connecting with other device, connecting with other device, different, product first, 4800/9600/19200/38400

SHR-6080P, SHR-6082N, SHR-6082P, SHR-6082P/CDM, SHR-6160P, SHR-6162N, SHR-6162P, SHR-6163P, SHR-6164P, SHR-6164P/CDM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 105
Download on canonical page 105 pages, 0 b

connecting with other device

CONNECTING THE RS-485 DEVICE

Connect the RS-485 device through the back port.

MFor example, you can connect and control the PTZ

camera which supports the RS-485 communication.

Transfer Type : You may select either Half Duplex or Full

Duplex as the data transfer type.

PTZ device

Rear

Half Duplex Type

Baud Rate : Supported Baud rates are 600/1200/2400/

4800/9600/19200/38400.

Data (–)

Data (+)

Tx(–)

M

Check if the RS-485 device is compatible with the

 

product first.

Pay attention not to change the polarity (+/-) of the

 

RS-485 device when connecting it.

Tx(+)

Full Duplex Type

Depending on camera’s type, connection polarity can be

different.

For further information, refer to the respective PTZ

Camera’s documentation.

Rx(+)

Rx(–)

Tx(–)

Rx(–)

Ex : DVR(TX+/-)SCC-C6433,35(RX+/-)

DVR(TX+/-)SCC-C6403,07(TX+/-)

Tx(+)

Rx(+)

 

22_ connecting with other device