Cino F700 manuals
Computer Equipment > Barcode Reader
When we buy new device such as Cino F700 we often through away most of the documentation but the warranty.
Very often issues with Cino F700 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Barcode Reader Cino F700 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Barcode Reader on our side using links below.
66 pages 683.49 Kb
2 DescriptionEnable Serial Response Time-out Presentation Control Light Source On Time Presentation Auto-sense Disable 4 WarrantyRegulatory 5 LED Eye SafetyLaser Eye Safety 6 Getting StartedConfigure Your FuzzyScan Appendix8 Universal HolderHand-freeSmartStand desired position for optimized scanning Please note that the SmartStand is not applicable for F400 Series imager 9 System CommandFamily Code Option Code 10 Programming ProceduresConventions of Programming Menu 11 Program & EndSystem List, Group & Master Default System List, Gro 12 Single scan selectionMultiple scans selection 13 Cycling scan selectionDual level selection 14 Parameter Selection15 ♦ User Defined Symbol ID ♦16 ♦ Symbology ID Transmission ♦Family Code Selection P.C Option Code 17 ♦ Readable Bar Code Setting ♦Readable Symbology Setting 18 ♦ Code 39/Code 32 Setting ♦Disable Code Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering Enable Code 39 buffering Disable Trioptic Code 39 Enable Trioptic Code Default (01) 01-Maximum this selection automatically Default (98) 98-Minimum Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously 19 ♦ Code 39 Setting ♦20 ♦ Codabar/NW-7Setting ♦Codabar Setting Disable Codabar Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Modulus 16 Modulus 10/weight Modulus 7 check DR Weight Modulus Runes (Modulus 10/weight 2) Codabar Min. Length Default (04) 22 ♦ UPC-A& UPC-ESetting ♦UPC Family Setting Disable UPC-A Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-Eexpansion Enable UPC-Eexpansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-Acheck digit transmission Enable UPC-Acheck digit transmission Disable UPC-Echeck digit transmission Enable UPC-Echeck digit transmission Disable UPC “leading 1” portion Enable UPC “leading 1” portion When enable UPC-AStandardization 24 ♦ EAN Setting, EAN Supplement Setting ♦25 ♦ EAN Security Level Setting ♦26 ♦ UCC Coupon Extended Code Setting ♦P.CParameter Selection 27 ♦ IATA & Interleaved 2 of 5 Setting ♦28 ♦ Code 25 Family Setting ♦Disable Standard/Industrial 2 of 5 Enable Standard/Industrial 2 of Disable Matrix 2 of 5 Enable Matrix 2 of Disable China Postal Code Enable China Postal Code 29 ♦ Code 11 & Code 93 Setting ♦Disable Code 11 Enable Code Select 1-checkdigit verification Select 2-checkdigit verification Enable Code 93 30 ♦ MSI/Plessey Setting ♦Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10check digit Select MOD 11-10check digit 31 ♦ Code 128 & UCC/EAN 128 Setting ♦Disable Code 128 and GS1-128 Enable Code 128 and GS1-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On 32 ♦ UK/Plessey Setting ♦Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F 33 ♦ Telepen Setting ♦Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode 34 ♦ GS1 DataBar Setting ♦Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded Only available for Expanded GS1 Databar Default (74) 74-Minimum 35 ♦ Linear-stacked& Korea Post Code Setting ♦36 ♦ Keyboard Layout (Language) Setting ♦Keyboard Layout USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (Spanish, QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Spain (Latin America, QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany(QWERTY) Iceland (QWERTY) Japan (DOS/V) Czech (QWERTY) Keyboard Interface Message String : 37 ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦38 ♦ Delay Setting ♦1-99(x5) msec Intercharacter Delay Interfunction Delay 39 ♦ Emulation Setting & Upper/Lower Case Setting ♦40 ♦ Record Suffix, Preamble ,Postamble Setting ♦STX/ETX Control Disable STX/ETX transmission Enable STX/ETX transmission data frame transmitted via serial interface CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) Postamble FIN Serial Interface Message String (RS232, USB COM) : 42 ♦ Protocol, ACK/NAK Setting ♦Handshaking Protocol None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) 3 times 0~255 times ACK Indication Disable ACK Time-outIndication Enable ACK Time-outIndication Disable ACK Indication Enable ACK Indication USB COM doesn’t support RTS/CTS handshaking protocol NAK Retry Count After preset NAK retry counts is received within the preset serial response If the preset ACK Indication: Disable: There’s neither LED nor beeping indication for this setting Enable: There’s a specific LED and beeping indication for this setting 43 ♦Time Out Setting, Baud Rate, Data Frame ♦3 seconds 200 mseconds 4 seconds 500 mseconds 5 seconds 800 mseconds 8 seconds 1 second 10 seconds 2 seconds 15 seconds 38.4K BPS 2400 BPS 19.2K BPS 1200 BPS 9600 BPS 57.6K BPS 4800 BPS 115.2K BPS 8, None, 1 7, Space 8, Odd 7, Mark 8, Even 7, None 8, Space 7, Odd 8, Mark 7, Even 8, None 44 ♦ Code 39/Code 128 Emulation ♦Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation Enable Full ASCII Code 39 emulation Enable Code 128 emulation 45 ♦ Operation Mode Setting ♦Operation Mode Low Power mode Force mode Trigger mode Toggle mode Presentation mode Diagnostic mode Alternative mode Level mode Flash mode Presentation Control Presentation mode L680/L780 laser imagers don’t support this function 46 ♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦47 ♦ Dollar Sign, Redundancy, Scan Rate Control♦Dollar Sign Control Dollar sign output as “ $ “ Dollar sign output as “ “ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “ To prevent potential miss reading Dynamic Fixed 48 ♦ Flash Duty Cycle, Delay Setting ♦49 ♦ Time-outSetting, Good Read Duration ♦50 ♦ Presentation Scanning Setting , Trigger Control♦Presentation Auto-sense Trigger Control 51 ♦ Laser Aiming Control♦52 ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦Enable 2 digits data length transmission If data length exceeds 99, 3-digitdata length will be transmitted Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Due to the resources used by this system 53 ♦ Data Formatter Setting ♦Formatter Control Select one bar code symbology Select all bar code symbologies 1st Insertion 2nd Insertion 3rd Insertion 4th Insertion 54 ♦ Data Verifier Setting ♦2nd Option CodeVerifier Control Identified Data Length Determine the identified data length for verification 1st Identified Character 2-digitschecking position; 1 identified character 2nd Identified Character 3rd Identified Character The Data Verifier is used to provide advanced verification for 55 ♦ Data Replacer Setting ♦Replacer Control 2-digitsidentified position; 1 replacement character 56 ♦ Data Organizer Setting ♦2nd Option CodeOrganizer Control 0 (Forward) 2-digitsidentified position; Forward/backward data transmission setting 2nd Organization Include/Exclude Control 57 Select a Bar Code SymbologyPosition Calculation Application Example 58 Programming ProcedureEach AIM Code Identifier contains the three-characterstring ]cm where: 59 ]cm]= Flag Character c = Code Character m = Modifier Character 60 Reserved ASCII 0 –Enable 61 HEXHEX/ASCII Table Example: PREAMBLE Hex/ASCII Table FIN (Finish) HEX/ASCII Reference Table End 64 FIN (Finish)END (Exit) 65 PROGRAMSystem Information List (Enter Programming Mode) (SYSLIST) Save User Default PowerTool Host Link User Default END Factory Default (Exit Programming Mode) Master Default
Also you can find more Cino manuals or manuals for other Computer Equipment.