Programming Manual

FuzzyScan

Configure Your FuzzyScan

Serial Interface Control

Record Suffix, Preamble ,Postamble Setting

PROGRAM

 

 

 

 

F_DEFAULT

 

 

 

 

 

 

Family Code Selection

P.C

Parameter Selection

 

Option Code

 

 

 

 

 

 

STX/ETX Control

SS

 

Disable STX/ETX transmission ￿

 

0

 

 

 

 

 

 

SS

 

Enable STX/ETX transmission

 

1

 

 

 

 

 

 

 

 

 

STX/ETX are two characters used to indicate the starting and ending of the total

 

 

 

 

 

data frame transmitted via serial interface.

 

 

 

 

 

 

 

 

Record Suffix

SS

 

None

 

0

 

 

CR (0DH) ￿

 

 

 

SS

 

 

1

 

SS

 

LF (0AH)

 

2

 

SS

 

CRLF (0D0AH)

 

3

 

SS

 

TAB (09H)

 

4

 

SS

 

SPACE (20H)

 

5

 

MS

 

User defined character (1 character)

 

6, (00-7F)

 

 

 

 

 

 

Preamble

SS

 

None ￿

 

FIN

 

 

 

 

 

 

MS

 

1-15 characters

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

Postamble

SS

 

None ￿

 

FIN

 

 

 

 

 

 

MS

 

1-15 characters

 

[00-7F], [FIN]

 

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

￿Serial Interface Message String (RS232, USB COM) :

STX

Preamble

Data Length

Prefix Symbol ID

Scanned Data

Suffix Symbol ID

Postamble

ETX

Record Suffix

1 character

1-15 characters

2-3 digits

1 or 2 characters

Variable length

1 or 2 characters

1-15 characters

1 character

1 character

34