Configure Your FuzzyScan

Manual

Programming Procedure

[Data Verifier]

￿Scan “Program” to enter the programming mode.

￿Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5).

￿Scan “Identified Data Length” and set the length to “16”.

￿Scan “1st Identified Character” and set the identified position to “00”, then set the identified character to “39” (Hex Code of 9).

[Data Formatter]

￿Scan “Formatter Control” and set bar code symbology to “48”.

￿Scan 1st Insertion” and set the identified position to “06”, then inserted characters to “09” (Hex Code of TAB), “53” (Hex Code of S), “4E” (Hex Code of N).

￿Scan “2nd Insertion” and set the identified position to “12”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection.

￿Scan “3rd Insertion” and set the identified position to “16”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection.

[Data Replacer]

￿Scan “Replacer Control” and set bar code symbology to “48”.

￿Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A).

[Data Organizer]

￿Scan “Organizer Control” and set bar code symbology to “48”.

￿Scan “1st Organization” and set the identified position to “16”, then set the data transmission to “0” (forward).

￿Scan “2nd Organization” and set the identified position to “17”, then set the data transmission to “1” (backward).

￿Scan “END” (Exit) to terminate the programming.

[Important Notice]

Please note that Condensed DataWizard will follow the preset working flow as below:

Verifier ￿ Formatter ￿ Replacer ￿ Organizer

Programming

FuzzyScan

So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.

52