Configure Your FuzzyScan

Wand/Laser Emulation Control

Code 39/Code 128 Emulation

PROGRAM

 

 

F_DEFAULT

 

 

 

 

Family Code Selection

P.C

Parameter Selection

Option Code

Code 39/Code 128 Emulation

SS

Disable standard Code 39 emulation

0

 

Enable standard Code 39 skip emulation ￿

 

 

SS

1

 

SS

Enable standard Code 39 replace emulation

2

 

SS

Enable Full ASCII Code 39 emulation

3

 

SS

Enable Code 128 emulation

4

 

 

 

 

￿[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.

￿[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.

Programming Manual

FuzzyScan

38