Programming Manual

FuzzyScan

Configure Your FuzzyScan

Keyboard Interface Control

Record Suffix, Preamble, Postamble & Caps Lock

PROGRAM

 

 

 

 

F_DEFAULT

 

 

 

 

 

 

Family Code Selection

P.C

 

Parameter Selection

Option Code

 

 

 

 

 

 

Record Suffix

SS

 

None

0

 

 

RETURN ￿

 

 

SS

 

1

 

SS

 

TAB

2

 

SS

 

SPACE

3

 

SS

 

ENTER (Numeric Key Pad)

4

 

SS

 

User defined character (1 character)

5, (00-7F)

 

 

 

 

 

Preamble

SS

 

None ￿

FIN

 

 

 

 

 

 

MS

 

1-15 characters

[00-7F], [FIN]

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

Postamble

SS

 

None ￿

FIN

 

 

 

 

 

 

MS

 

1-15 characters

[00-7F], [FIN]

 

 

 

 

 

 

 

 

Maximum 15-character input; scan “FIN” to terminate this selection.

 

 

 

 

 

 

 

 

Caps Lock Control

SS

 

“Caps Lock Off” State ￿

0

 

 

 

 

 

 

SS

 

“Caps Lock On” State

1

 

SS

 

Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)

2

 

 

 

 

 

Caps Lock Release Control

SS

 

“Caps Lock On, Caps Off” ￿

0

 

 

 

 

 

 

SS

 

“Caps Lock On, Shift Off”

1

 

 

 

 

 

 

￿The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions for you.

￿Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.

31