Programming Manual
FuzzyScan
Configure Your FuzzyScan
Symbology Reading Control
♦ EAN Security Level Setting ♦PROGRAM |
|
|
| F_DEFAULT |
|
|
|
|
|
Family Code Selection | P.C | Parameter Selection |
| Option Code |
|
|
|
|
|
UPC/EAN Security Level | SS | Level 0 |
| 0 |
| Level 1 |
|
| |
| SS |
| 1 | |
| SS | Level 2 |
| 2 |
|
|
| ||
|
|
|
|
|
|
| Only available for |
|
|
|
|
|
|
|
EAN Supplement Control | SS | Disable all specific prefix supplement digital output |
| 0 |
|
|
|
| |
| SS | Enable all specific prefix supplement digital output |
| 1 |
| SS | Enable 491 Supplement Digit Output |
| 2 |
| SS | Enable 978/979 Supplement Digit Output |
| 3 |
| SS | Enable 977 Supplement Digit Output |
| 4 |
| SS | Enable 378/379 Supplement Digit Output |
| 5 |
| SS | Enable 414/419 Supplement Digit Output |
| 6 |
| SS | Enable 434/439 Supplement Digit Output |
| 7 |
|
|
|
|
|
UPC/EAN Security Level
The scanner offers three levels of decode security for UPC/EAN bar codes:
Level 0: If you are experiencing misread of
Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding
Level 2: If you are experiencing misread of
EAN Supplement Control
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.
If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5 supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.
19