Configure Your FuzzyScan

Symbology Reading Control

Code 39 Setting

PROGRAM

 

 

F_DEFAULT

 

 

 

 

Family Code Selection

P.C

Parameter Selection

Option Code

 

 

 

 

Code 39 Security Level

SS

Level 0

0

 

 

 

 

SS

Level 1

1

 

SS

Level 2 ￿

2

 

SS

Level 3

3

 

 

 

 

￿Code 39 Security Level

The scanner offers four levels of decode security for Code39 bar codes:

Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.

Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.

Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.

Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.

Programming Manual

FuzzyScan

13