Cino F700BT manuals
Computer Equipment > Scanner
When we buy new device such as Cino F700BT we often through away most of the documentation but the warranty.
Very often issues with Cino F700BT begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Scanner Cino F700BT is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Scanner on our side using links below.
87 pages 1.03 Mb
1 International Edition, Rev. B52 Description1 – Add “Indications” Serial Response Time-out Presentation Control Light Source On Time Presentation Auto-sense Disable3 Remove ”Scan Voting” and add “Scan Rate Control ”Quantity Output Format Rev. A7 Nov 10 Baud Rate – Cancel Baud Rate 300/600 BPS Buzzer Tone Adjust – Modify No power-onbeep behavior. The setting of Rev. A8 Jan 2 No power-onbeep will impact both Bluetooth Scanner and Smart Cradle Add “Beeping Control” setting Rev. A9 Mar 04 Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to Add ”Code 39 Security Level” Add “NAK Retry Count” Rev. B1 Mar 22 Add “ACK/NAK Transmission Indication” Add “Numeric Bar Codes ” Add “Connecting Apple iOS Devices Quick Sets” Page 19, 29, 34, 67 UCC/EAN-128was renamed GS1-128 Rename “ACK/NAK Transmission Indication” to “ACK Indication” Rename the 2 parameters of the “ACK Indication” (Disable Disable ACK Time-outIndication, Enable Enable ACK Time-out Indication) Add 2 new parameters to “ACK Indication”.(Disable ACK Indication, Enable ACK Indication) Add 6 parameters to “Serial response time -out”.(800 mseconds, 3 seconds seconds, 8 seconds, 10 seconds, 15 seconds) Cancel the parameter "User defined value (seconds)” of “Serial response time -out” Add “Laser Aiming Control” function 4 Rev. No5 WarrantyRegulatory 7 Getting StartedConfigure Your FuzzyScan Appendix 8 F700BT Series ScannerHB2110 Smart Cradle (Base) F600BT Series Scanner HB2100 Charging Cradle (Base) 9 Install the BatteryCharging the Battery 10 PAIR ModePICO Mode HID Mode SPP Master/Slave Mode 13 Clone Function15 Establish SPP Master Connection16 Establish SPP Slave Connection18 How to Transmit Stored Data19 Using Quantity Feature25 Reference Manual26 ♦ User Defined Symbol ID ♦27 ♦ Symbology ID Transmission ♦Family Code Selection P.C Option Code 28 ♦ Readable Bar Code Setting ♦29 ♦ Code 39/Code 32 Setting ♦Disable Code Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering Enable Code 39 buffering Disable Trioptic Code 39 Enable Trioptic Code Default (01) 01-Maximum this selection automatically Default (98) 98-Minimum Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously 30 ♦ Code 39 Setting ♦Level Level 2 Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes: Reference Manual 31 ♦ Codabar/NW-7Setting ♦Codabar Setting Disable Codabar Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Modulus 16 Modulus 10/weight Modulus 7 check DR Weight Modulus Runes (Modulus 10/weight 2) Codabar Min. Length Default (04) 33 ♦ UPC-A& UPC-ESetting ♦UPC Family Setting Disable UPC-A Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-Eexpansion Enable UPC-Eexpansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-Acheck digit transmission Enable UPC-Acheck digit transmission Disable UPC-Echeck digit transmission Enable UPC-Echeck digit transmission Disable UPC “leading 1” portion Enable UPC “leading 1” portion When enable 35 ♦ EAN Setting ♦37 ♦ UCC Coupon Extended Code Setting ♦P.CParameter Selection 38 ♦ IATA & Interleaved 2 of 5 Setting ♦39 ♦ Code 25 Family Setting ♦Disable Standard/Industrial 2 of 5 Enable Standard/Industrial 2 of Disable Matrix 2 of 5 Enable Matrix 2 of Disable China Postal Code Enable China Postal Code 40 ♦ Code 11 & Code 93 Setting ♦Disable Code 11 Enable Code Select 1-checkdigit verification Select 2-checkdigit verification Enable Code 93 41 ♦ MSI/Plessey Setting ♦Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10check digit Select MOD 11-10check digit 42 ♦ Code 128 & UCC/EAN 128 Setting ♦Disable Code 128 and GS1-128 Enable Code 128 and GS1-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On 43 ♦ UK/Plessey Setting ♦Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F 44 ♦ Telepen Setting ♦Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode 45 ♦ GS1 DataBar Setting ♦Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded Only available for Expanded GS1 Databar Default (74) 74-Minimum 46 ♦ Linear-stacked& Korea Post Code Setting ♦47 ♦ Keyboard Layout (Language) Setting ♦USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (Spanish, QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Spain (Latin America, QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany(QWERTY) Iceland (QWERTY) Japan (DOS/V) Czech (QWERTY) Keyboard Interface Message String : 48 ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦49 ♦ Delay Setting ♦1-99(x10) msec 1-99(x5) msec 50 ♦ Emulation Setting & Upper/Lower Case Setting ♦51 ♦ Record Suffix, Preamble ,Postamble Setting ♦STX/ETX Control Disable STX/ETX transmission Enable STX/ETX transmission data frame transmitted via serial interface CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) Serial Interface Message String (RS232, USB COM) : 53 ♦ Protocol, ACK/NAK Setting ♦None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) 3 times 0~255 times ACK Indication Disable ACK Time-outIndication Enable ACK Time-outIndication Disable ACK Indication Enable ACK Indication USB COM doesn’t support RTS/CTS handshaking protocol ACK/NAK handshaking protocol is workable under following conditions: 1)Pair mode by using RS232 or USB COM interface 2)SPP master or slave mode NAK Retry Count After preset NAK retry counts is received within the preset serial response If the preset ACK Indication: Disable: There’s neither LED nor beeping indication for this setting 55 ♦Time Out Setting, Baud Rate, Data Frame ♦F_DEFAULT 3 seconds 200 mseconds 4 seconds 500 mseconds 5 seconds 800 mseconds 8 seconds 1 second 10 seconds 2 seconds 15 seconds 38.4K BPS 2400 BPS 19.2K BPS 1200 BPS 9600 BPS 57.6K BPS 4800 BPS 115.2K BPS 8, None, 1 7, Space 8, Odd 7, Mark 8, Even 7, None 8, Space 7, Odd 8, Mark 7, Even 8, None 56 ♦ Code 39/Code 128 Emulation ♦High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space Initial Signal State High Level (5Vdc) Low Level (0Vdc) Determine the initial state of output voltage level 10 msec 30 msec 15 msec 50 msec 20 msec. 100 msec 25 msec Delay time before data transmission Extremely short Long Short Medium Time base of minimum narrow bar 1:2 1:2.5 1:3 Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation Enable Code 128 emulation ♦ Operation Mode ♦Operation Mode Trigger mode Presentation mode 57 Reference Manual58 ♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦Buzzer Tone Adjust Good Read Indicator 59 ♦ Dollar Sign Control, Redundancy, Scan Rate Control ♦Dollar Sign Control Dollar sign output as “ $ “ Dollar sign output as “ “ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “ To prevent potential miss reading Dynamic Fixed 61 ♦ Time-outSetting, Good Read Duration ♦62 ♦ Presentation Scanning Setting, Laser Aiming Control ♦3 mins 5 mins 10 mins Only available for FuuzzyScan Laser model Presentation Sensitivity Level 5 Laser Aiming Control Only available for L series laser imaging scanner You can disable or enable laser aiming line when you scan PDF barcode 63 ♦1D Barcode Direction Indication Transmission, etc. ♦64 ♦ Out-of-rangeScanning, Sleep Time-outControl ♦Out-of-rangeScanning Link Supervision Time-out 3 secs Only available in PAIR & PICO modes 6 (x5) minutes 0-99(x5) minutes 1 minute 0-99minutes If you don’t want the scanner to enter sleep mode, please set time-outto “0” Out-of-range The Link Supervision 65 ♦ Batch Scanning Setting ♦Batch Scanning Link Control Radio disable Radio enable All On cradle Scan barcode Transmission The Batch Scanning Link Control is a 66 ♦ Batch Scanning Data Transmission Setting ♦User define As many times as the quantity indicates <Quantity><Field Delimiter><Scanned Data <Scanned Data><Field Delimiter><Quantity Disable (scanned data only) Leading with MAC address (MAC address and scanned data) Leading with ID No. (scanner ID and scanned data) 67 ♦ Bluetooth Device Name & Security Setting♦Default device name User define, 1-16characters Default Bluetooth PIN Code User define, 1-8numbers Bluetooth Authentication The default Bluetooth Device Name is “CINO 68 ♦ Bluetooth Other Settings ♦69 ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦Enable 2 digits data length transmission If data length exceeds 99, 3-digitdata length will be transmitted Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Due to the resources used by this system 70 ♦ Data Formatter Setting ♦Formatter Control Select one bar code symbology Select all bar code symbologies 1st Insertion 2nd Insertion 3rd Insertion 4th Insertion 71 ♦ Data Verifier Setting ♦2nd Option CodeVerifier Control Identified Data Length Determine the identified data length for verification 1st Identified Character 2-digitschecking position; 1 identified character 2nd Identified Character 3rd Identified Character The Data Verifier is used to provide advanced verification for 72 ♦ Data Replacer Setting ♦Replacer Control 2-digitsidentified position; 1 replacement character 73 ♦ Data Organizer Setting ♦Organizer Control 1st Organization 0 (Forward) 2-digitsidentified position; Forward/backward data transmission setting 2nd Organization Include/Exclude Control 74 Select a Bar Code SymbologyPosition Calculation Application Example 75 Programming ProcedureAppendix Each AIM Code Identifier contains the three-characterstring ]cm where: 76 ]cm]= Flag Character c = Code Character m = Modifier Character 77 Reserved ASCII 0 –Enable 78 HEXHEX/ASCII Table Example: PREAMBLE Hex/ASCII Table FIN (Finish) End HEX/ASCII Reference Table 79 Reference Manual86 HB2100 Charging Cradle IndicationHB2110 Smart Cradle Indications
Also you can find more Cino manuals or manuals for other Computer Equipment.