Garland STW286A manuals
Kitchen Appliance > Range
When we buy new device such as Garland STW286A we often through away most of the documentation but the warranty.
Very often issues with Garland STW286A begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Range Garland STW286A is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Range on our side using links below.
Garland STW286A Operation Manual
56 pages 1.14 Mb
FOR YOUR SAFETY: WARNING: INSTALLATION AND OPERATION MANUALGARLAND STARFIRE SENTRY COMBINATION RANGE, MODEL STW286A3 TABLE OF CONTENTSINSTALLATION........................6 OPERATION..........................10 MAINTENANCE & CLEANING. . . . . . . . . . 12 WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . 20 4 DIMENSIONS5 SPECIFICATIONSINTRODUCTION 6 INSTALLATIONINTRODUCTION continuedGeneral Information Rating Plate Safety Product Usage 7 ClearancesLocation Appliances Equipped with Casters Ventilation & Air Supply Gas Connection: 8 TABLE A. Gas Flow Rate (total)TABLE B. Heat Input Per Burner TABLE C. Manifold Pressure / Injector Size TABLE D. Adjustment Pressure for MIN Valve Position (Hot Top section) TABLE E. Aeration Shutter Setting / Pilot Flame Length 9 Commissioning:Burner Adjustments: Griddle /Solid Hot Top Burner Hot Top Minimum Flame Setting Oven Burner 10 OPERATIONSafety concerns SOLID TOP (STW286A) OFF IGNITION FULL FLAME LOW FLAME OVEN/GRIDDLE TOPGriddles Preparing A New Griddle Lighting The Griddle Seasoning The Griddle Shut Down Solid Hot Tops (STW286A) Lighting The Solid Hot Top 11 OPERATION continuedOven Convection Oven Lighting the Oven Shut Down 12 OPERATION continuedMAINTENANCE & CLEANING 16 CONVERSION INSTRUCTIONS17 FAULT FINDINGGas Taps Door Switch Control Panel Rocker Switches 18 REPLACEMENT OF PARTSThermostat Heat-On Lamp Gas Control Valve Front Cooling Fan Motor 19 REPLACEMENT OF PARTS continuedIgnition Control Hot Top Ignition Momentary Switch Hot Top Spark Generator 20 WIRING DIAGRAMSREV (With Robertshaw Ignition Control Module)REV.# DATE DR.DESCRIPTION REVISIONS WIRING DIAGRAM STW286A 21 REV REV.# DATE DR.DESCRIPTION REVISIONS WIRING DIAGRAM STW286ADEC 10/2003NAN.B. 47 47 54 21 21 (With Robertshaw Ignition Control Module)22 For Models Manufactured From Oct /05/2005, Serial # 0510100130790 To Mar/23/2009 S/N 0903100100822 REV.# DATE DR.DESCRIPTION REVISIONS (With Johnson Control Module)WIRING DIAGRAM STW286AJULY 10/2003NAN.B. 48 47 54 11 23 For Models From Oct /05/2005, Serial # 0510100130790 To Mar/23/2009 S/N 0903100100822 REV.# DATE DR.DESCRIPTION REVISIONS (With Johnson Control Module)WIRING DIAGRAM STW286AJULY 10/2005NAN.B. 48 47 54 11 24 For All ModelsREV.# DATE DR.DESCRIPTION REVISIONS SCHEMATIC DIAGRAM, 120VDEC 10/2003NAN.B. 230V 50/60Hz, 2.3 AMPS 120V 50/60Hz, 4.5 AMPS TOTAL MAXIMUM LOAD: 220-240V 0.8VA 100-120V 0.6VA HOT TOP IGNITION MODULE MINIMUM REQUIRED FLAME SENSE CURRENT 0.7 MICROAMPS 24V, 50/60Hz, 0.25A SP845 IGNITION MODULE: 24V, 50/60Hz, 0.4A MAX. SOLENOID VALVES (EACH): 230V MODEL 4656N 50/60 HZ, 18W 115V MODEL 4606N 50/60 HZ, 18W PAPST COOLING FAN: 230V, 50/60Hz, 1.8 AMP MOTOR: 1/3hp, 115V, 50/60Hz, 3.6 AMP, 25 For All ModelsMOTOR: 1/3hp, 115V, 50/60Hz, 3.6 AMPREV.# DATE DR.DESCRIPTION REVISIONS SCHEMATIC DIAGRAM, 230V 120V 50/60Hz, 4.5 AMPS TOTAL MAXIMUM LOAD: FLAME SENSE CURRENT 0.7 MICROAMPS MINIMUM REQUIRED 24V, 50/60Hz, 0.25A SP845 IGNITION MODULE: 24V, 50/60Hz, 0.4A MAX. SOLENOID VALVES (EACH) 230V, 50/60Hz, 1.8 AMP 230V 50/60Hz, 2.3 AMPS Pice n 4517957 Rev. 13 (02/10/11) Page 25 32 Pour tous les modles 230V 50/60Hz, 2.3 AMPS 120V 50/60Hz, 4.5 AMPS TOTAL MAXIMUM LOAD: FLAME SENSE CURRENT 0.7 MICROAMPS MINIMUM REQUIRED 24V, 50/60Hz, 0.25A SP845 IGNITION MODULE: 24V, 50/60Hz, 0.4A MAX. SOLENOID VALVES (EACH) 230V, 50/60Hz, 1.8 AMP MOTOR: 1/3hp, 115V, 50/60Hz, 3.6 AMPREV REVISIONS DR.DESCRIPTION DATE REV.# SCHEMATIC DIAGRAM, 230V Pice n 4517957 Rev. 13 (02/10/11)Page 24 33 Pour tous les modles120V 50/60Hz, 4.5 AMPS TOTAL MAXIMUM LOAD: 220-240V 0.8VA 100-120V 0.6VA HOT TOP IGNITION MODULE MINIMUM REQUIRED FLAME SENSE CURRENT 0.7 MICROAMPS 24V, 50/60Hz, 0.25A SP845 IGNITION MODULE: 24V, 50/60Hz, 0.4A MAX. SOLENOID VALVES (EACH): 230V MODEL 4656N 50/60 HZ, 18W 115V MODEL 4606N 50/60 HZ, 18W PAPST COOLING FAN: 230V, 50/60Hz, 1.8 AMP MOTOR: 1/3hp, 115V, 50/60Hz, 3.6 AMP,REV DEC 10/2003NAN.B. REVISIONS DR.DESCRIPTION DATE REV.# SCHEMATIC DIAGRAM, 120V Pice n 4517957 Rev. 13 (02/10/11) Page 2354 11REV 48 47 JULY 10/2005NAN.B. WIRING DIAGRAM STW286AREVISIONS DR.DESCRIPTION DATE REV.# 34 (avec module de commandeJohnsonPice n 4517957 Rev. 13 (02/10/11)Page 2254 11 REV 48 47 JULY 10/2003NAN.B. WIRING DIAGRAM STW286AREVISIONS DR.DESCRIPTION DATE REV.# 35 (avec module de commandeJohnsonPice n 4517957 Rev. 13 (02/10/11) Page 21 36 Pour modles fabriqus jusqu'au 4 octobre 2005, No de srie 0509100130513 & 54 21REV 47 47 DEC 10/2003NAN.B. WIRING DIAGRAM STW286AREVISIONS DR.DESCRIPTION DATE REV.# Pice n 4517957 Rev. 13 (02/10/11)Page 20 37 SCHMAS DE CBLAGEPour modles fabriqus jusqu'au 4 octobre 2005, No de srie 0509100130513 & REV 48 47 NOV 29/97NAV.C. WIRING DIAGRAM STW286AREVISIONS DR.DESCRIPTION DATE REV.# Ventilateur de refroidissement avant Gnrateur d'tincelles de plaque de cuisson Moteur cuisson Interrupteur rappel d'allumage de plaque de Commande d'allumage 38 REMPLACEMENT DES PICES suiteRobinets de gaz commande Robinet de commande du gaz Tmoin de chauage Thermostat Commutateurs bascule du panneau de Interrupteur de porte 39 REMPLACEMENT DES PICES40 RECHERCHE DES PANNES41 INSTRUCTIONS DE CONVERSION42 Divers43 Four convectionFour Gril"B" Dial Shaft "A"Calibration talonnage du thermostat Robinet de gaz Nettoyage du brleur de veilleuse 44 GrilGril / Plaque de cuisson pleine Nettoyage des brleurs importante) Grils faire et ne pas faire Instructions de nettoyage (Pour une accumulation Instructions de nettoyage (aprs chaque utilisation) Allumage du four Acier inoxydable Surfaces mailles/peintes Filtre d'vacuation Suggestions dutilisation Arrt 45 FONCTIONNEMENT suiteMAINTENANCE ET NETTOYAGEApprtage du gril Allumage de la plaque de cuisson pleine Fours convection Four Plaques cuisson pleines (STW286A) Arrt 46 FONCTIONNEMENT suite47 FONCTIONNEMENTFLAMME MAXIMALEPrparation dun gril neuf Grils PLAQUE CHAUFFANTE FOUR/GRILPLAQUE CHAUFFANTE ALLUMAGE TEINTCommandes Problmes de scurit FLAMME BASSEAllumage du gril 48 Mise en service :Rglage minimum de amme de plaque de cuisson Brleur de four Brleur de gril/plaque de cuisson pleine Rglages des brleurs: 49 TABLE A. Dbit de gaz (total)TABLE E. Rglage du volet daration / Longueur de amme de veilleuse TABLE D. Pression de rglage pour la position MIN du robinet (section plaque de cuisson) TABLE C. Pression du collecteur / Taille dinjecteur TABLE B. Dbit calorique par brleur 50 DgagementsConnexion du gaz: Emplacement Ventilation et alimentation en air Appareils quips de roulettes 51 INSTALLATIONINTRODUCTION suiteUtilisation du produit Scurit Plaque signaltique 52 SPCIFICATIONSINTRODUCTION 53 DIMENSIONS54 TABLE DES MATIRESMAINTENANCE ET NETTOYAGE ....... 12 SCHMAS DE CBLAGE...............20 REMPLACEMENT DES PICES .........18 RECHERCHE DES PANNES ............ 17 INSTRUCTIONS DE CONVERSION......16 FONCTIONNEMENT ..................10 INSTALLATION........................ 6 INTRODUCTION ......................5 SPCIFICATIONS ...................... 5 DIMENSIONS ......................... 4 INFORMATION IMPORTANTES .........2 POUR VOTRE SCURIT: AVERTISSEMENT: 56 INSTRUCTIONS DINSTALLATION MODLE STW 286 A SENTRY DE GARLAND SCUISINIRE COMBINE STARFIRE ET DUTILISATION
Also you can find more Garland manuals or manuals for other Kitchen Appliance.