HP D2D4112 G2 manuals
Computer Equipment > Computer Drive
When we buy new device such as HP D2D4112 G2 we often through away most of the documentation but the warranty.
Very often issues with HP D2D4112 G2 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Computer Drive HP D2D4112 G2 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Computer Drive on our side using links below.
43 pages 2.52 Mb
1 Abstract3 3 Replacing the system motherboard4 Battery/Flash Backed Write Cache (BBWC or FBWC) module failures 5 The HP SmartArray P410i and P812/P411 RAID controllers and HP SAS 4 6 The HP SmartArray P212 RAID controller (HP D2D2502 G2, 2504 G27 The HP SmartArray P400 RAID controller (D2D4004/4009/2500 G1) 5 G2 models:•HP D2D4324 G2 (12–disk) •HP D2D4312 G2 (12–disk) •HP D2D4112 and HP D2D4106 G2 (12–disk) •HP D2D2502 and HP D2D2504 G2 (4–disk) G1 models: •HP D2D4112 (12–disk) •HP D2D4004 (6–disk) •HP D2D4009 (12–disk) •HP D2D2500 series (4–disk) Installation Instructions http://www.hp.com/support/manuals Table 1 Identifying the correct server guide 6 How do I tell whether I have a G1 or G2 product7 Using the ProLiant Guide with HP D2D4324 G2 models8 Using the ProLiant Guide with HP D2D4312 G2 models9 Using the ProLiant Guide with HP D2D4106/4112 G2 models•The CPU is Intel Xeon X5550 (Spare P/N 490070-001)– there are two per system ◦HP Smart Array P212/Zero Memory Controller: 462828-B21 ◦512MB BBWC -Cacheand BBWC: 462967-B21 Figure 3 Rear view of the HP D2D4106/4112 G2 Using the ProLiant Guide with HP D2D2502/2504 G2 models The CPU is the Intel Xeon E5520, part number •The HP D2D has four removable hard disks •There is no optical media storage 10 Using the ProLiant Guide with HP D2D4112 G1 models11 Using the ProLiant Guide with HP D2D4004 and 4009 G1 models12 Using the ProLiant Guide with HP D2D2502 G1 models13 Using the ProLiant Guide with HP D2D2503 G1 models14 Using the ProLiant Guide with HP D2D2504 G1 modelsThe AMD Opteron 2384 2.7GHz (75W), part number The following tasks are described in this guide: •How to replace the flash memory module •How to replace the motherboard •How to replace the HP Smart Array RAID controller HP D2D Backup System User Guide Related documentation (page 42) 15 Part numberTroubleshooting procedure 17 Figure 10 HP D2D2502 and HP D2D2504 G2 Series flash memory module18 Figure 11 HP D2D 4112, HP D2D4004 or HP D2D4009 G1 flash memory moduleFigure 12 HP D2D2500 G1 Series flash memory module 19 •Set the J27 jumper on HP D2D4106/4112 G2 and HP D2D2502/2504 G2 products•Update BIOS IDs on all products •Reinstate iLO2 licences on all G2 products iLO2 licenses 1.Log on to the iLO2 GUI 2.Select the Administration Tab 3.Select Licensing and make a note of the License Key NOTE: G1 products do not support iLO2 SAAP licence (HP D2D4324 and D2D4312) 20 1.Reboot the system2.During the POST screen, when advised, hit any key to see further messages NOTE: This section is not relevant for HP D2D4324/4312 models The following diagram shows the location of the J27 jumper on the motherboard Figure 13 Location of the J27 jumper 21 Table 3 J27 jumper settingsG2 products For all G2 products you must: http://www.hp.com/support/downloads Change the Performance options, as shown in the following table Table 4 RBSU settings Change the BIOS ID, as shown in the following table Table 5 BIOS IDs for G2 products 22 G1 products23 Part numbers for a replacement cache modules are as follows:•G1 products: BBWC = 398648–001 •G2 products apart from HP D2D4324: BBWC = 462976–001 •HP D2D4324 G2: FBWC = 534562-B21 HP D2D4324, D2D4312, D2D4106 and D2D4112 Figure 14 Example HP D2D4312 Summary page showing battery failure 24 HP D2D432425 HP D2D4312HP D2D4106/4112 G2 26 HP D2D2502/2504 G2HP D2D4004/4009 and HP D2D2502/3/4 G1 27 HP D2D4112 G128 Figure 24 Location of LEDS on the BBWC29 HP D2D4324The HP D2D4324 has four RAID controllers Figure 25 HP D2D4324, location of the P812 controller and HP SAS expander card WARNING HP D2D4312 The HP D2D4312 has three RAID controllers 30 Figure 26 HP D2D4312, location of the P411 controller and HP SAS expander cardPart numbers cache module failure NOTE: It is not necessary to reinstate the license with the P812 card 32 5.Install the SAAP licenseTable 7 Cabling to HP SAS expander card (HP D2D4312) 33 Figure 27 Cabling showing the SAS expander cardFigure 28 Cabling showing the backplanes 34 •HP D2D2502 G2•HP D2D2504 G2 •HP D2D4106 G2 •HP D2D4112 G2 Figure 29 HP D2D4106/4112 G2 models, location of the P212 controller Figure 30 HP D2D2502/2504 G2 models, location of the P212 controller The required parts are: •HP Smart Array P212/Zero Memory Controller, part number 462828-B21 •512 MB BBWC -Cacheand BBWC, part number 462967-B21 35 •Summary page: RAID catastrophically failedSummary page: Storage—RAID RAID device is not available •RAID page (HP D2D2502/2504): RAID device is not available 36 Figure 31 Inserting a P212 card into an HP D2D4106/4112Figure 32 Inserting a P212 card into an HP D2D2502/2504 6.HP D2D4106/4112 Backup Systems only: Reinstate the SAAP license 37 •HP StoreOnce D2D4004 and D2D4009 G1•HP StoreOnce D2D2500 series (HP D2D2502/3/4) G1 Figure 33 HP D2D4004 and HP D2D4009, location of the P400 controller Figure 34 HP D2D2500 series, location of the RAID controller The component parts have the following part numbers: •P400 card: 441823–001 •512 MB memory: 405835–001 •BBWC: 398648–001 •BBWC cable assembly: 409125–001 38 Identifying a P400 card failure•RAID page: RAID device is not available RAID page: Figure 35 Location of LEDs on the P400 controller card 40 Identifying a P800 card failure
Also you can find more HP manuals or manuals for other Computer Equipment.