321 Studios FLF110D48E, FH110D48E, FLR140D60E warranty Danger, To Remove Burner Only, During Removal

Models: FH110D60E FH085D36E FLR110D60E FLR085D36E FLR110D48E FC085D36E FLF110D60E FLF085D36E FLR140D60E FH110D48E FLF110D48E

1 39
Download 39 pages 2.46 Kb
Page 33
Image 33
TO REMOVE BURNER ONLY

TO REMOVE BURNER ONLY

Disconnect fuel line, power cord and wires from T, T on primary control. Loosen (3) 1/4 inch bolts securing burner mounting flange. Twist burner counterclockwise and pull straight back away from the furnace. (See Figure 19.)

TO REMOVE THE ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM

Disconnect fuel line, power cord and wires from T, T on primary control. Remove (6) 5/16 inch bolts from around front plate. Next remove (2) 5/16 inch nuts from upper right and left hand corners of the front plate. Pull entire assembly straight back away from furnace.

BE CAREFUL NOT TO TIP ASSEMBLY UP OR DOWN AS IT MAY DAMAGE THE COMBUSTION CHAMBER. (See Figure 20.)

FIGURE 20

REMOVAL OF ENTIRE COMBUSTION CHAMBER MOUNTING SYSTEM

!DANGER

*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.

STEP 3:

REMOVE (2) NUTS

IN THE TOP LEFT

AND RIGHT CORNERS

OF BURNER PLATE.

STEP 4:

PULL BURNER ASSEMBLY

STRAIGHT OUT TO PREVENT

DAMAGE TO CHAMBER

DURING REMOVAL.

CHAMBER

BURNER

PLATE

STEP 2:

REMOVE (6) BOLTS

AROUND PERIMETER

OF BURNER PLATE

STEP 1:

DISCONNECT "T-T" WIRES,

POWER CONNECTIONS, AIR MIS-1837

BOOT (OPTIONAL) AND OIL LINES TO BURNER.

Manual 2100-422 Page 31

Page 33
Image 33
321 Studios FLF110D48E, FH110D48E Danger, To Remove Burner Only, To Remove The Entire Combustion Chamber Mounting System