Patch Panels

Patch panels weaken signals, thereby reducing achievable link distances. 3Com includes the use of one patch panel in the 150 meter link distance calculation. However, each additional patch panel in the link reduces the 150 meter link distance by approximately 10 meters.

In the example in Figure 2-2, if two patch panels were used between the top right PC and the top right concentrator, the link distance of 150 meters would have to be shortened to 140 meters. This is because the maximum allowable link distance on 22 gauge wire using 10BASE-T signaling with two intervening patch panels is 150 meters minus approximately 10 meters.

Note that a patch panel installed between the bottom right PC and the bottom left concentrator would not affect the link since it is only 20 meters.