Table 4-1. Troubleshooting With the Port Status LEDs (Continued)

LED State

Indication

Possible

Troubleshooting

Problem

Suggestions

 

 

 

 

 

 

 

 

1 Blink

Link

Cable not

Connect cable.

 

Integrity

connected

 

 

Error

 

 

 

 

 

Cable broken

Check cable with cable

 

 

 

 

 

 

 

tester. Repair or replace

 

 

 

 

cable.

 

 

 

 

 

 

 

 

Cable too long

Try a shorter cable.

 

 

 

 

 

 

 

 

Remote

Enable Link Integrity at

 

 

 

connection has

remote connection or if

 

 

 

Link Integrity

the remote link does not

 

 

 

disabled

have Link Integrity,

 

 

 

 

disable Link Integrity at

 

 

 

 

local connection.

 

 

 

 

 

 

 

 

Weak or no

Change Squelch level

 

 

 

signal - link

from high to low (low

 

 

 

distance too

setting does not

 

 

 

long

conform to the

 

 

 

 

10BASE-T standard).

 

 

 

 

 

 

 

 

Bad port

Try another port.

 

 

 

 

 

 

 

 

Device attached

This is not a problem.

 

 

 

to transceiver at

 

 

 

 

other end is not

 

 

 

 

powered on

 

 

 

 

 

 

Troubleshooting 4 - 3