3M 6700-50 SC 50 m MM 250/900 m, 8700-UPC Remove the connector from the port on the finisher lid

Models: 8700-UPC 6700-50/LOMMF SC 50 m LOMMF 250/900 m

1 18
Download 18 pages 14.46 Kb
Page 14
Image 14
5.6Remove the connector from the port on the finisher lid.

5.2Wet the top surface of the finishing disc with 2 squirts of de-ionized water using the spray bottle provided. Avoid using excessive amounts of water. Close the lid fully and ensure the latch is engaged.

Note: Wetting the disc surface is important because it carries off glass particles that have been removed. Failure to wet the disc results in poor connector performance.

5.3Insert the connector into the port on the 3MNano-finisher lid making certain it is fully engaged. Push until a click is heard.

Push down

further

5.4Press the release button on the side of the finisher. The button will stay depressed until the finishing sequence is complete. It pops back up automatically. Allow this to happen by keeping clear of the button during the sequence.

5.5Rotate the input knob one full turn with a single continuous motion. The finisher automatically stops the input knob after one full turn.

5.6Remove the connector from the port on the finisher lid.

Note: The nano-finisher is best stored dry – inside and out. Open the lid as shown in step 5.1, and allow to dry.

Push down

until it clicks

14

78-0013-1746-6-E

Page 14
Image 14
3M 6700-50 SC 50 m MM 250/900 m, 8700-UPC, SC 250/900m manual Remove the connector from the port on the finisher lid