3M MP8650 manual Lamp Information, Metal Halide Projector Lamp, Display Lamp Operation Hours

Models: MP8650

1 32
Download 32 pages 37.28 Kb
Page 21
Image 21
Section 6: Lamp Information

Section 6: Lamp Information

6-1. Metal Halide Projector Lamp

If the projected image appears dark, the lamp may be getting old and in need of replacement. Under normal operating conditions, the lamp should last approximately 1000 hours. However, after time, the lamp brightness will slowly grow dimmer.

￿Note

The TEMPERATURE indicator will come on if the lamp becomes too hot. If this happens, wait for the fan motor to stop running, turn the power off and let the projector cool. Check for airflow blockage, clean the air filter then turn the power on. If the TEMPERATURE indicator comes on again, call customer service or your dealer for assistance.

Display Lamp Operation Hours

You must turn both the projector lamp and main power OFF to reset the lamp hours.

aPress power button (Figure 4-1, side of projector) to turn projection lamp OFF.

bSwitch projector power OFF (Figure 2-1, back of projector) to turn main power off.

cPress and hold the INPUT button (Figure 4-1, side of projector).

dWhile pressing the INPUT button, switch main power ON (Figure 2-1, back of projector). This will display the Lamp Timer Clock.

eRead the number of lamp usage hours.

fCheck the RESET field to make sure it is set to NO. If RESET is set to YES, press the INPUT button to switch it back. (See note)

gPress power button (Figure 4-1, side of projector) to turn projection lamp OFF and exit the lamp timer clock display mode.

hSwitch projector power OFF (Figure 2-1, back of projector) to turn main power off.

￿Note

Changing RESET to YES will zero the hour clock. This should only be done by a qualified technician when a new lamp is installed.

Change Lamp Message

After 1000 hours of lamp operation, the message ªChange Lampº will display for 30 seconds each time the machine is powered on. This message is an indication that it is time to install a fresh lamp.

For best results, the lamp should be replaced after 1000 hours of usage.

DFor 110V machines, the lamp can be replaced by the user (See Technical Appendix for instructions)

DFor 220V machines, the lamp must be replaced by a qualified service repair technician.

Contact your nearest Service Repair Center or the Technical Assistance Center at:

In U.S. or Canada: 1-800-328-1371

In other locations, contact your local 3M Sales office.

3M 1997

3M