4XEM IPCAMWFD manual Parameter pair

Models: IPCAMWFD

1 88
Download 88 pages 25.56 Kb
Page 65
Image 65

http://<servername>/cgi-bin/admin/setparam.cgi?

[nosync=<value>&]<parameter>=<value>

[&<parameter>=<value>…][&return=<return page>]

parameter

value

 

description

 

 

 

 

 

 

 

nosync

0, 1

 

Specifies that there should be no sync (write) of

 

 

 

the corresponding configuration file on flash. If

 

 

 

parameter is omitted, a sync write will occur.

 

 

 

(note: this parameter must be put at begin of

 

 

 

parameter list)

 

 

 

 

 

 

 

 

 

 

 

<group>_<name>.

value

to

Assign

<value>

to

the

parameter

 

assigned

 

<group>_<name>..

 

 

 

 

 

 

return

<return page>

Redirect to the page <return page> after the

 

 

 

parameter is assigned. The <return page> can

 

 

 

be a full URL path or relative path according the

 

 

 

the current path. If you omit this parameter, it

 

 

 

will redirect to an empty page.

 

 

 

 

(note: The return page can be a general HTML

 

 

 

file(.htm, .html) or a server script executable

 

 

 

(.vspx) file. It can not be a CGI command. It can

 

 

 

not have any extra parameters. This parameter

 

 

 

must be put at end of parameter list)

 

 

 

 

 

 

 

 

Return:

HTTP/1.0 200 OK\r\n Content-Type: text/html\r\n Context-Length: <length>\r\n \r\n

<parameter pair>

where <parameter pair> is <parameter>=<value>\r\n

[<parameter pair>]

Only the parameters that you set and readable will be returned.

- 61 -