Lighting Instructions for the G(B/W) 1000 through 2500 models
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A.THIS APPLIANCE DOES NOT HAVE A PILOT. IT IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE BURNER. DO NOT TRY TO LIGHT THE BURNER BY HAND.
B.BEFORELIGHTING:SMELLALLAROUNDTHEAPPLIANCE AREA FOR GAS. BE SURE TO SMELL NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE FLOOR.
WHAT TO DO IF YOU SMELL GAS
•DO NOT TRY TO LIGHT ANY APPLIANCE.
•DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.
•IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS.
•IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
C.USE ONLY YOUR HAND TO PUSH IN OR TURN THE GAS CONTROL KNOB. NEVER USE TOOLS. IF THE KNOB WILL NOT PUSH IN OR TURN BY HAND, DON’T TRY TO REPAIR IT. CALLA QUALIFIED SERVICE TECHNICIAN. FORCE OR ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION.
D.DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
E.DO NOT OPERATE APPLIANCE UNLESS UNIT IS FILLED WITH WATER AND WATER LINES ARE FULLY OPEN.
OPERATING INSTRUCTIONS
1.STOP! READ THE SAFETY INFORMATION THE NEXT STEP ABOVE ON THIS LABEL.
2.SET THE SYSTEM CONTROLLER TO THE LOWEST SETTING.
3.TURN OFF ALL ELECTRIC POWER TO APPLIANCE.
4.THIS APPLIANCE IS EQUIPPED WITH AN IGNITION DEVICE WHICHAUTOMATICALLY LIGHTS THE BURNER. DO NOT TRY TO LIGHT THE BURNER BY HAND.
5.REMOVE CONTROLACCESS PANEL.
6.REFER TO DIAGRAMS ABOVE. TURN TOP KNOB OF GAS CONTROL CLOCKWISE TO “OFF” POSITION, (FIG. A).
7.WAIT FIVE (5) MINUTES TO CLEAR OUTANY GAS. THEN SMELL FOR GAS, INCLUDING NEAR THE FLOOR. IF YOU SMELL GAS,
STOP ! FOLLOW “B” IN THE SAFETY INFORMATION ABOVE ON THIS LABEL.
IF YOU DON’T SMELL GAS, GO TO THE NEXT STEP.
8.TURN TOP KNOB OF GAS CONTROL COUNTER- CLOCKWISE TO “ON” POSITION, (FIG. B).
9.REPLACE CONTROLACCESS PANEL.
10.TURN POWER SWITCH TO “ON” POSITION.
11.SET THE SYSTEM CONTROLLER TO DESIRED SETTING.
12.IF THE APPLIANCE WILL NOT OPERATE, FOLLOW THE INSTRUCTIONS “TO TURN OFF GAS TO THE APPLIANCE” AND CALL YOUR SERVICE TECHNICIAN OR GAS SUPPLIER.
TO TURN OFF GAS TO APPLIANCE
1. SET THE SYSTEM CONTROLLER TO THE LOWEST | 4. REFER TO DIAGRAMS ABOVE. TURN TOP KNOB OF GAS |
SETTING. | CONTROL CLOCKWISE (TO “OFF” POSITION, (FIG. A). |
2.TURN POWER SWITCH ON APPLIANCE TO “OFF” 5. REPLACE CONTROLACCESS PANEL. POSITION.
3.REMOVE ACCESS PANEL TO EXPOSE GAS CONTROL.
24