TABLE 3: RECOVERY CAPACITIES

 

 

 

 

Temperature Rise - Degrees °F (°C)

 

 

 

 

 

Input Rating

Gal/Liter

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

MODEL

BTU/Hr. (kW)

per Hr.

(22.2°)

(27.7°)

(33.3°)

(38.8°)

(44.4°)

(50°)

(55.5°)

(61.1°)

(66.7°)

(72.2°)

GW - 1000

990,000 (290.1)

LPH

9526

7620

6350

5443

4763

4234

3810

3462

3175

2930

 

 

GPH

2520

2016

1680

1440

1260

1120

1008

916

840

775

GW - 1300

1,300,000 (380.9)

LPH

12508

10006

8339

7148

6256

5560

5005

4547

4169

3848

 

 

GPH

3309

2647

2206

1891

1655

1471

1324

1203

1103

1018

GW - 1500

1,500,000 (439.5)

LPH

14432

11548

9620

8248

7216

6415

5772

5247

4812

4442

 

 

GPH

3818

3055

2545

2182

1909

1697

1527

1388

1273

1175

GW - 1850

1,850,000 (542.0)

LPH

17800

14239

11865

10172

8902

7912

7122

6471

5935

5477

 

 

GPH

4709

3767

3139

2691

2355

2093

1884

1712

1570

1449

GW - 2100

2,100,000 (615.3)

LPH

20204

16163

13472

11548

10104

8981

8082

7348

6736

6218

 

 

GPH

5345

4276

3564

3055

2673

2376

2138

1944

1782

1645

GW - 2500

2,490,000 (729.6)

LPH

23958

19168

15971

13691

11979

10648

9582

8713

7987

7371

 

 

GPH

6338

5071

4225

3622

3169

2817

2535

2305

2113

1950

TABLE 4: HEAT EXCHANGER PRESSURE DROP

GB Models-Flow, Head Loss and Temperature Rise

 

 

20 Deg. F Rise

30 Deg. F Rise

40 Deg. F Rise

Maximum Flow Rate

Minimum Flow Rate

 

 

GPM

PD-FT

GPM

PD-FT

GPM

PD-FT

GPM

PD-FT

Deg. F

GPM

PD-FT

Deg. F

MODEL

 

 

Head

 

Head

 

Head

 

Head

Rise

 

Head

 

Rise

GB - 1000

83.16

5.1

55.4

2.7

41.6

1.5

154

12.2

11

42

1.5

 

40

 

GB - 1300

109.2

7.2

72.8

4.2

54.6

3.2

154

14.5

14

55

3.2

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GB - 1500

126

10.1

84

6.3

63

4.3

154

16.3

17

64

4.3

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GB - 1850

154

18.5

103.6

10.1

77.7

6.4

154

18.5

20

78

6.4

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GB - 2100

 

n/a

n/a

117.6

14.5

88.2

8.3

154

21.3

23

89

8.3

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GB - 2500

 

n/a

n/a

139.4

18.5

104.6

11.6

154

23.2

28

105

11.6

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: GW models (GB optional) are equipped with pumps capable of handling 50 equivalent feet

 

 

 

 

 

(15.2 m) of normal pipe fittings.

 

 

 

 

 

 

 

 

 

3