WARNING

UNDER NO CIRCUMSTANCES SHOULD THE INPUT EXCEED THE RATE SHOWN ONTHE HEATERRATINGPLATE.OVERFIRING COULD RESULTIN DAMAGE OR SOOTING OF THE HEATER.

CATHODIC PROTECTION

CAUTION

HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN USED FOR A LONG PERIOD OF TIME (GENERALLY TWO WEEKS OR MORE). HYDROGEN GAS IS EXTREMELY FLAMMABLE. To reduce the risk of injury under these conditions, it is recommended that a hot water faucet be opened for several minutes before using any electrical appliance connected to the hot water system. If hydrogen is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at the time it is open.

PRECAUTIONS

IFTHEUNITISEXPOSEDTOTHEFOLLOWING,DONOTOPERATEHEATER UNTIL ALL CORRECTIVE STEPS HAVE BEEN MADE BY A QUALIFIED SERVICEMAN.

1.FLOODINGTOORABOVETHELEVELOFTHEBURNERORCONTROLS

2.EXTERNALFIRING

3.DAMAGE

4.FIRINGWITHOUTWATER

5.SOOTING

NEVEROPERATETHEHEATERWITHOUTFIRSTBEINGCERTAINITISFILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF VALVE OPENING OF THE HEATER.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE TO THE APPLIANCE.

GENERAL INFORMATION

POWER BURNER

The initial start-up procedure of the unit is provided on page 18.

The sequence of operation of the unit is provided on page 15.

It is important to note that the controller has a reset button on the control box, Figure 1. The reset button is a safety device and would not normally be used.

HIGH LIMIT

The high limit (not adjustable) is factory set to cutout at 202°F. The controller must be manually reset by depressing the reset button on front of the control when water temperature drops to below 160°F.

TABLE 4

BTH 120

BTH 150

BTH 120

GAS SUPPLY SPECIFICATIONS

& 250

& 199

150 & 199

 

Natural Gas

Natural Gas

L.P. Gas

Max. Gas Supply Press. W.C.

14.0

14.0

14.0

Nominal Gas Supply Press. W.C

7.0

7.0

11.0

Minimal Gas Supply Press. W.C.

5.0

4.5

11.0

Manifold Press. W.C.

4.0

3.5

10.0

 

 

 

 

HIGH ALTITUDE INSTALLATIONS

WARNING

BTH HEATERS ARE CERTIFIED FOR USE WITHOUT MODIFICATION FOR ALTITUDES UP TO 6500 FEET. INSTALLATIONS ABOVE 6500 FEET MAY REQUIREREPLACEMENTOFTHEBURNERORIFICE. CALLTHETECHNICAL CENTER @ (800) 627-1953 FOR REQUIREMENTS.

Some gas utility companies derate their gas for altitude, making it unneccessary to install high altitude orifices. Call the local gas or utlity company to verify BTU content.

Due to the input rating reduction at high altitudes, the output rating of the appliance is also reduced and should be compensated for in the sizing of the equipment for applications.

MAINTENANCE

GENERAL

KEEP APPLIANCE AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS. (SEE WARNING ON PAGE 5, LOCATING THE HEATER).

Water heater maintenance includes periodic tank flushing and cleaning, and removal of lime scale. The unit should be inspected and adjusted to maintain proper combustion. Refer to the following table. A periodic inspection of the venting system should be made. Where used, the water circulating pump should be oiled.

MAINTENANCE SCHEDULE

Following are the instructions for performing some of the recommended maintenance. Unit inspection and adjustment should be performed by a competent technician.

COMPONENT

OPERATION

INTERVAL

REQUIRED

 

 

 

 

Tank

Sediment

Monthly

Flushing

 

Removal

 

 

 

 

 

 

 

 

 

 

Tank

Lime Scale

Semi

UN-LIME®

 

Removal

Annually

Delimer

 

 

 

 

 

 

 

 

Anode

Inspect

Semi

Replace as

Rods

 

Annually

Required

 

 

 

 

 

 

 

 

Relief Valve

Inspect

Semi

 

 

 

Annually

 

 

 

 

 

 

 

 

 

 

 

 

SAE No. 20

Circulating

Oiling

Four Months

non-detergent

Pump (1)

 

 

motor oil

 

 

 

 

 

 

 

 

 

Clean Inlet

 

 

Blower

Screen and

As Required

Soft Brush

 

Blower Wheel

 

 

 

 

 

 

 

 

 

 

Vent System

Inspect

Every 3

Joints should

 

 

Months

be sealed

 

 

 

 

(1) If furnished with oiling provision.