A.O. Smith HYB-90N warranty Water Piping - Mixing Valve Usage

Models: HYB-90N

1 60
Download 60 pages 51.2 Kb
Page 11
Image 11
WATER PIPING - MIXING VALVE USAGE

WATER PIPING - MIXING VALVE USAGE

SUGGESTED PIPING

ARRANGEMENT

FOR TOP

CONNECTIONS

SHUT-OFF VALVE

TEMPERED POTABLE WATER

COLD WATER

INLET

THERMAL

EXPANSION

Water (Potable) Heating: All models are considered TANK Manual background

MIXING

VALVE

(OPTIONAL)

PIPE INSULATION (RECOMMENDED)

METAL

DRAIN PAN

TEMPERED POTABLE WATER

TEMPERATURE- PRESSURE RELIEF VALVE

DISCHARGE

PIPE (DO NOT CAP OR PLUG)

6 in. (15cm)

MAX.

AIR GAP

DRAIN VALVE

FLOOR

TO SUITABLE DRAIN

 

DRAIN

FIGURE 3

This appliance has been design certified as complying with

DO NOT use any pumps, valves, or fittings that are not

ANSI Z21.10.3/CSA 4.3 (latest revision) for water heaters

compatible with potable water.

and is considered suitable for:

DO NOT use valves that may cause excessive restriction

Water (Potable) Heating: All models are considered

to water flow. Use full flow ball or gate valves only.

suitable for water (potable) heating.

DO NOT use any lead based solder in potable water

 

lines. Use appropriate tin-antimony or other equivalent

 

material.

 

DO NOT tamper with the gas control/thermostat, igniter,

 

flammable vapor sensor or temperature and pressure

 

relief valve. Tampering voids all warranties. Only qualified

 

service technicians should service these components.

 

DO NOT use with piping that has been treated with

 

chromates, boiler seal, or other chemicals.

 

DO NOT add any chemicals to the system piping which

 

will contaminate the potable water supply.

Please note the following:

The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, PEX or polybutylene. DO NOT use PVC water piping.

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, and the physically or developmentally disabled. If anyone using hot water from this heater fits into one of these

www.hotwater.com

11

Page 11
Image 11
A.O. Smith HYB-90N warranty Water Piping - Mixing Valve Usage, Water Potable Heating All models are considered