Clearing Password Check and BIOS Recovery

This section provides you with the standard operating procedures of clearing password and BIOS recovery for Acer Aspire 5241 Series. The machine provides one Hardware Open Gap on main board for clearing pass- word check, and one Hotkey for enabling BIOS Recovery.

Clearing Password Check

Steps for Clearing BIOS Password Check

If users set BIOS Password (Supervisor Password and/or User Password) for a security reason, BIOS will ask the password during systems POST or when systems enter to BIOS Setup menu. However, once it is necessary to bypass the password check, users need to short the HW Gap to clear the password by the following steps:

1.Power Off the system, and remove HDD, AC and Battery from the machine.

2.Disconnect the RTC Battery cable and locate the J1 jumper.

3.Use an electric conductivity tool to short the two points of the HW Gap.

4.Plug in AC, keep the short condition on the HW Gap, and press Power Button to power on the system till BIOS POST finish. Then remove the tool from the HW Gap.

5.Restart system. Press F2 key to enter BIOS Setup menu.

6.If there is no Password request, BIOS Password is cleared. Otherwise, please follow the steps and try again.

NOTE: These steps are only for clearing BIOS Password (Supervisor Password and User Password).

Clear CMOS Jumper

Item

Description

Location

 

 

 

J1

Clear CMOS Jumper

Memory Bay - under DIMM modules

 

 

 

142

Chapter 5

Page 152
Image 152
Acer 5241 manual Clearing Password Check and Bios Recovery, Clear Cmos Jumper, Steps for Clearing Bios Password Check