Acer 65PE B Replacing the Lamp, Lamp is not well attached, Temperature is too high, Normal status

Models: 65PE

1 33
Download 33 pages 36.55 Kb
Page 18
Image 18
2.Lamp is not well attached

Figure

17 Lamp replacement warning signal II

Figure 18 Lamp

replacement

warning signal II

 

2.Lamp is not well attached

If the LED blinks rapidly, it indicates that the lamp is not attached properly.

3.Temperature is too high

If the projector’s internal temperature is too hot to operate safely, the LED will blink slowly for one minute and then the lamp will turn off automatically.

4.Normal status

If the LED light is off, it means the lamp and temperature inside the projector are normal.

3.Temperature is too highCaution:

The lamp indicator will light when the lamp becomes too hot. Turn off the power and let the projector cool for 45 minutes, then turn it on again. If the indicator is still shining, contact your dealer.

B Replacing the Lamp

Replacing the lamp

When replacing the lamp, turn off the projector and unplug the AC cord. Wait 45 minutes so that the lamp can cool. High-pressure lamp when hit, may explode if improperly handled.

4.Normal statusCaution:

Dispose of used lamps in accordance with local authorities.

As the lamp is made of glass, do not apply shocks to it or scratch it.

Also, do not use an old lamp, as this could cause the lamp to explode.

If it seems that the lamp has exploded (for example, an explosive sound is heard), disconnect the power cord from the outlet and ask your dealer to replace the lamp. The lamp is covered by a front glass panel and an air-tight structure, but, in rare cases, the reflector and the inside of the projector may be damaged by scattered, broken pieces of glass, which could cause injury while being handled.

i.Turn the main power switch off and disconnect the power cord from the outlet.

ii.Remove the lamp cover.

If hot, the lamp could cause burns. Wait for about 45 minutes until lamp has cooled down.

Loosen a screw and remove the cover.

English 14

Page 18
Image 18
Acer 65PE B Replacing the Lamp, Lamp is not well attached, Temperature is too high, Normal status, Replacing the lamp