setup speed range is from 1 ~ 15. Refer to below table for more information.
| PAN (degree/sec.) | TILT (degree/sec.) |
Speed 1 | 10 | 8 |
Speed 2 | 23 | 12 |
Speed 3 | 35 | 22 |
Speed 4 | 45 | 30 |
Speed 5 | 55 | 40 |
Speed 6 | 65 | 50 |
Speed 7 | 75 | 58 |
Speed 8 | 185 | 185 |
Speed 9 | 205 | 210 |
Speed 10 | 225 | 240 |
Speed 11 | 250 | 275 |
Speed 12 | 280 | 305 |
Speed 13 | 320 | 335 |
Speed 14 | 365 | 365 |
Speed 15 | 400 | 400 |
♦DWELL TIME
The DWELL TIME is the duration time that the speed dome will stay at the sequence point, and the range is from <0> to <127> seconds. The speed dome will go to the next sequence point when the DWELL TIME is up. If the setting is <0>, the speed dome will stay at this sequence point until users manually move the speed dome.
♦RUN SEQUENCE
User can command the speed dome camera to run the selected Sequence line manually.
♦EXIT
Select the item to exit the SEQUENCE menu.
B-3-15 AUTOPAN