Acumen SDR2-USB manual Service Support, Exception Codes

Models: SDR2-USB

1 41
Download 41 pages 57.05 Kb
Page 29
Image 29

SDR2-USB Configuration Guide rev 1.0

Service and Support

6

6. Service and

Support

6.1 Exception Codes

The following are common error codes encountered when using DataBridge SDR2-USB products. To determine which error has occurred, watch the "exception" indicator on the SDR2-USB's front panel and count the number of rapid blinks. Each sequence is separated by a 1 second pause in the blink pattern.

Exception 2: Root Directory Full

A FAT (FAT16) root directory can have only 512 directory entries (fewer if long filenames are used). Delete files from the root directory, record to a subfolder in the root directory, or use FAT32 formatting to overcome this limitation.

Exception 3: Disk Full

The disk has no (or almost no) available space for files. Delete files from the disk to ensure space is available.

27

Page 29
Image 29
Acumen SDR2-USB manual Service Support, Exception Codes