17
B. IGNITION CONTROLSHot Surface Ignition Module Replacement(refer to burner illustration on page 11)
1. Discontinue electrical power to the dryer.
2. Disconnect wire from S1 and GND on the HSI (Hot
Surface Ignition) module.
3. Disassemble ignitor from burner by removing the one
(1) self tapping screw.
4. Reverse procedure for installation of new ignitor.
NOTE: Before reestablishing electrical power to the dryer visually check the following (refer to
illustration above).
5. Reestablish procedure for installation of new ignitor.
Flame Sensor Probe Replacement
1. Discontinue electrical power to the dryer.
2. Disconnect the ๎‚“red๎‚” wire from the flame sensor
probe which goes to S2 on the HSI (Hot Surface
Ignition) module.
3. Disassemble flame sensor probe from burner by
removing the one (1) self tapping screw.
4. Reverse procedure for installation of new flame sensor probe.
NOTE: Before reestablishing electrical power to the dryer visually check the following (refer to
illustration above).
5. Reestablish procedure for installation of new ignitor.
Hot Surface Ignitor Flame Sensor Probe
1. Disconnect electrical power to the dryer.
2. Disconnect the hot surface ignitor wires S1 and ground (GND) on the HSI (Hot Surface Ignition) Module.
3. Disasemble Hot Surface Ignitor Probe from the burner by removing the one (1) self tapping screw.
4. Reverse procedure for installation of new hot surface ignitor.
NOTE: Before reestablishing electrical power to the dryer visually check the following (refer to
illustration above).