50
IMPORTANT

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR PHASE 6 MODELS

This dryer was manufactured with a manual reset burner hi-limit and tumbler/lint chamber hi-limit thermostat
which is monitored by the Phase 6 computer. If either manual reset thermostat is open prior to start of the drying
cycle, the dryer will start momentarily and then shut down, the Phase 6 computer will display an error code with
an audio indication. If the tumbler/lint chamber hi-limit thermostat is open, the display will read dRUM SAFETY
FAIL. If the burner hi-limit thermostat is open, the display will read bURNER SAFETY FAIL.
If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable error
code described above along with an audio indication. If the drum temperature is above 100º F (38º C), the dryer
will continue to run with no heat for three (3) minutes or until the drum temperature has flattened below 100º F
(38º C). The clear/stop button on the Phase 6 keypad (touchpad) must be pressed to clear the error condition.
The open manual reset hi-limit thermostat must be reset manually prior to the start of the next cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner operation.
The location of the burner hi-limit is on the right side of the burner box and the tumbler hi-limit is located in the lint
chamber area.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.