The Status Screen, illustrated in Figure 13, provides quick access to status information for both the LTU and NTU, in addition to any regenerators.

Type “3” to view the status screen for REG #1, as illustrated in Figure 14. If the circuit involves a second REG, press “4” from the REG #1 Status Screen to view the REG#2 Status Screen.

Figure 13 and Figure 14 consolidate current information for the HDSL and E1 interfaces. A key to

the information provided is found in the center of the screen. Arrows indicate the key statistics, which apply to both the remote and customer site components.

Indications of Loopback and Sealing Current (if present) are given at the bottom of the first key column. Status and configuration information for the LTU and NTU E1 signals are located in the center of the Status Screen near the bottom.

Shelf:

1

Slot:

5

 

Total Access System

 

 

 

04/07/01 09:15

Unacknowledged Alarms:

 

 

MAJOR MINOR

 

 

 

 

 

 

Circuit ID:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LTU

 

 

 

LTU/NTU Status

 

 

 

 

NTU

 

Loop 1 <Network> Loop 2

 

 

 

 

 

 

Loop 1 <Customer> Loop 2

01 dB

 

01 dB

 

<-

Loss

->

 

 

01 dB

 

 

01 dB

Yes

 

 

Yes

 

<-

Sync

->

 

 

Yes

 

 

Yes

000/00000

000/00000

 

<-ES

15M/24H ->

 

000/00000

 

 

000/00000

000/00000

000/00000

 

<-SES 15M/24H ->

 

000/00000

 

 

000/00000

000/00000

000/00000

 

<-UAS 15M/24H ->

 

000/00000

 

 

000/00000

Loopbacks Inactive

 

Sealing Current Present

 

Loopbacks Inactive

LTU Signal Quality

LTU E1

 

 

NTU E1

 

NTU Signal Quality

[X]

9

[X]

 

 

 

 

 

 

 

[X]

9

[X]

[X]

8

[X]

CAS

<-

Frame ->

CAS

 

[X]

8

[X]

[X]

7

[X]

HDB3

<-

Code

->

HDB3

 

[X]

7

[X]

[X]

6

[X]

ENABLED <-

CRC4

-> ENABLED

 

[X]

6

[X]

[X]

5

[X]

METH1

<-

CFM

->

METH1

 

[X]

5

[X]

[X]

4

[X]

00000

<-

BPV

->

00000

 

[X]

4

[X]

[X]

3

[X]

00000

<-

ES

->

00000

 

[X]

3

[X]

[X]

2

[X]

00000

<-

SES

->

00000

 

[X]

2

[X]

[X]

1

[X]

00000

<-

UAS

->

00000

 

[X]

1

[X]

[X]

0

[X]

None

<- Alarms ->

None

 

[X]

0

[X]

1.

 

Zero Registers

 

 

Selection:

 

 

3.

 

REG1 Status

2.

 

LTU/NTU Status

 

‘?’ - System Help Screen

 

4.

 

REG2 Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 13. Status Screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shelf:

1 Slot:

5

 

Total Access System

 

 

 

04/07/01 09:14

Unacknowledged Alarms:

 

MAJOR MINOR

 

 

 

 

 

 

 

Circuit ID:

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop 1

<Network> Loop 2

 

 

 

 

 

Loop 1 <Customer> Loop 2

00 dB

 

 

00 dB

 

<-

 

Loss

->

 

00 dB

 

 

00 dB

Yes

 

 

 

Yes

 

<-

 

Sync

->

 

Yes

 

 

Yes

000/00000

000/00000

 

<-ES

15M/24H ->

000/00000

 

000/00000

000/00000

000/00000

 

<-SES

15M/24H ->

000/00000

 

000/00000

000/00000

000/00000

 

<-UAS

15M/24H ->

000/00000

 

000/00000

Loopback

Inactive

 

Sealing Current Present

 

Loopback

 

Inactive

[X]

 

9

[X]

 

 

 

 

 

 

 

 

[X]

 

9

[X]

[X]

 

8

[X]

 

 

 

 

 

 

 

 

[X]

 

8

[X]

[X]

 

7

[X]

____ LP1

____ LP1

____

____

[X]

 

7

[X]

[X]

 

6

[X]

LTU

REG1

REG2

NTU

[X]

 

6

[X]

[X]

 

5

[X]

===N

C===

====

[X]

 

5

[X]

[X]

 

4

[X]

[X]

 

4

[X]

[X]

 

3

[X]

===N

C===

====

[X]

 

3

[X]

[X]

 

2

[X]

____

____

____

____

[X]

 

2

[X]

[X]

 

1

[X]

 

 

LP2

 

LP2

 

 

 

[X]

 

1

[X]

[X]

 

0

[X]

 

 

 

 

 

 

 

 

[X]

 

0

[X]

1.

Zero Registers

 

 

Selection:

 

 

 

3.

REG1 Status

2.

LTU/NTU Status

‘?’ - System Help Screen

 

4.

REG2 Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 14. REG #1 Status Screen

61182007L1-5A

Section 61182007L1-5, Issue 1

11

Page 11
Image 11
ADTRAN 3060 specifications LTU E1, CAS HDB3, HDB3 Enabled CRC4, Cfm, Bpv, Ses, Uas, LTU REG1 REG2 NTU, LP2