Figure 21 illustrates the Alarm Options Screen. This option allows the user to first set a 15-minute threshold for both ES and SES alarms and subsequently to categorize the crossing of those thresholds as a MINOR or MAJOR alarm. Setting a threshold to 900 will disable it.

6. HDSL DEPLOYMENT GUIDELINES

The ADTRAN HDSL system is designed to provide E1 services over loops designed to comply with ETSI guidelines. Deployment guidelines are given below.

1.All loops are non-loaded only.

2.For loops with 0.4 mm cable, the maximum loop length including bridged tap lengths is 2.7 km.

3.For loops with 0.5 mm cable, the maximum loop length including bridged tap lengths is 4.7 km.

4.Any single bridged tap is limited to 500 m.

5.Maximum number of bridged taps is 2.

7. MAINTENANCE

The ADTRAN Total Access LTU requires no routine maintenance. In case of equipment malfunction, use the faceplate Bantam jack connectors to help locate the source of the problem.

ADTRAN does not recommend that repairs be performed in the field. Repair services may be obtained by returning the defective unit to the ADTRAN Customer Service RMA Department.

Shelf: 1 Slot: 5

Total Access System

04/07/01 09:22

Unacknowledged Alarms:

MAJOR MINOR

 

 

Circuit ID:

 

 

 

 

Alarm Options

Current Settings

1.

ES Alarm Level

=

Major

2.

SES Alarm Level

=

Major

3.

ES Alarm Threshold

=

000

4.

SES Alarm Threshold

=

000

Selection:

‘?’ - System Help Screen

Figure 21. Alarm Options Screen