ADTRAN 3060 specifications Revision History, Installation

Models: 3060

1 30
Download 30 pages 12.49 Kb
Page 2
Image 2

The HDSL local loop operates as two independent subsystems each operating over a single twisted pair. The LTU communicates over these two twisted pairs to the HDSL Transceiver Unit - Remote end (NTU). Each subsystem carries half of the total bandwidth along with a small amount of overhead used for maintenance and performance monitoring.

System power and alarm bus connections are made through the backplane of the Total Access 3010 shelf. E1 and HDSL signals are connected through the 50- pin shelf connectors related to each individual slot.

The LTU contains onboard fuses. If a fuse opens, it supplies a -48 Vdc voltage to the fuse alarm bus and all front panel indicators will be Off. These fuses are not field replaceable.

The Total Access 3010 LTU uses a DC-to-DC converter to derive its internal logic and span powering voltages from the -48 Vdc office supply. The Total Access 3010 LTU can span power REGs and NTUs as listed above. When used with REGs and NTUs, the LTU can span power one REG and an

NTU at less than -120 Vdc. Span powering voltages meet all requirements of IEC 950.

REVISION HISTORY

This is the first issue of this practice. Future changes to this document will be summarized in this paragraph.

2. INSTALLATION

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

After unpacking the unit, inspect it for damage. If damage is discovered, file a claim with the carrier, then contact ADTRAN. See Warranty and Customer Service.

The Total Access 3010 LTU occupies one line card slot in a Total Access 3010 shelf. Power and alarm signals are provided to the card through the backplane of the shelf. E1 and HDSL loop signals are connected to the mass termination shelf connectors corresponding to the slot the unit occupies. See Figure 2 for LTU edge connector wiring.

P2, Row A

 

P2, Row B

P2, Row C

 

1

 

1

Chassis ground

1

- 48 Volt DC A

2

- 48 Volt return

2

Chassis ground

2

- 48 Volt DC A

3

 

3

 

3

 

4

 

4

 

4

HDSL Loop 1 Ring (facility)

5

 

5

 

5

HDSL Loop 1 Tip (facility)

6

 

6

HDSL Loop 2 Ring (facility)

6

HDSL Loop 2 Tip (facility)

7

 

7

 

7

 

8

 

8

 

8

 

9

 

9

 

9

 

10

 

10

Fuse alarm

10

 

11

 

11

 

11

 

12

 

12

 

12

 

13

 

13

 

13

 

14

 

14

 

14

 

15

 

15

 

15

 

16

 

16

 

16

 

17

 

17

 

17

 

18

 

18

 

18

 

19

 

19

 

19

 

20

 

20

 

20

 

21

 

21

 

21

 

22

 

22

 

22

 

23

 

23

 

23

 

24

 

24

 

24

 

25

 

25

Receive G.703 Ring backup connection

25

Receive G.703 Tip backup connection

26

 

26

Transmit G.703 Ring backup connection

26

Transmit G.703 Tip backup connection

27

 

27

 

27

 

28

 

28

 

28

 

29

 

29

Receive G.703 Ring normal connection

29

Receive G.703 Tip normal connection

30

 

30

Transmit G.703 Ring normal connection

30

Transmit G.703 Tip normal connection

31

 

31

 

31

- 48 Volt DC B

32

 

32

- 48 Volt return

32

- 48 Volt DC B

Figure 2. LTU Edge Connector Wiring

2

Section 61182007L1-5, Issue 1

61182007L1-5A

Page 2
Image 2
ADTRAN 3060 specifications Revision History, Installation