Outlet hole - Only for models DF 6260, DF 6260-ml/1 and CHDF 6260

(extractor-filter version)

When used as an extractor unit, the hood

must be fitted with a 150mm diameter

 

 

hose.

 

 

Only for model DF 6260 - DF 6260-ml/1:

 

 

Should there already be a pipe of

 

 

diameter 125 mm that ducts to the

 

 

outside through the walls or roof, it is

 

 

possible to use the 150/125 mm reduction

 

 

flange provided. In this case the hood will

Fig. 8a

Fig. 8b

be slightly more noisy.

Fix the flange on the hood outlet hole, using 2 screws. Fig. 8a.

Filter version only

Fix the deflector to the flange. Fig. 8b.

Outlet hole - Only for model DF 6160(extractor-filter version)

When used as an extractor unit, the hood must be fitted with a 120mm diameter hose.

The dimensions and position of the air outlet are given in figure 9.

Using the adapter, Ø100, Ø110 and Ø125 mm exhausting pipes can be used.

Ø125 mm exhausting hose: insert the adapter on the flange and remove, using a proper tool, the upper unused Ø 100 and Ø 110 mm rings of the adapter.

Ø110 mm exhausting pipe: same procedure, but removing the Ø 100 mm ring only.

Ø100 mm exhausting pipe: apply the adapter on the flange.

A

Fig. 9

Fig. 10

72

Page 72
Image 72
AEG DF 6160, CHDF 6260, DF6260-ML/1 installation instructions Only for model DF 6260 DF 6260-ml/1, Filter version only