19.To Remove the Oven Door Seal

SERVICING  WARNING

Disconnect from electricity before servicing. Check appliance is safe when you have finished.

19.To Remove the Oven Door Seal

Open oven door. The seal is held in place by small hooks on the rear face. At the corner pull seal diagonally away from the door centre until that hook is released.

Proceed to the next hook and release it in a similar way, and so on. Use force if the hooks are stiff, as the old seal will be discarded.

When fitting new seal, position the seal join at the bottom. Hook the new seal in one of the corner holes of the door, and proceed round the door snapping in each hook in turn.

20.To Adjust the Oven Door Catch Keeper

Open the oven door and slacken the locknut at the keeper base.

Adjust the keeper inward or outward as required, until the desired door operation is obtained. Check the door seal with a strip of paper.

Re-tighten the locknut.

21.To Replace the Cooling fan

Turn off the power at the circuit breaker.

Lift up the cooktop - see section 4

The fan is now accessible under the cooktop at the rear.

Disconnect the electrical connections and unscrew the 4 fan fixing screws.

Reassemble in reverse order.