HE/001132

Page 9 of 92

 

Document No.001132, Revision 2.0

Agfa HealthCare

NodeID Livelink : 14140190

14 June, 2007

 

 

2NETWORKING

2.1Implementation Model

2.1.1Application Data Flow Diagram

local remote

Remote

Request to send images & GSPS

Request to Print

film sheets

Query RIS

Query RIS by

AccessionNumber

Archive Images

Print Images

DICOM Store

Application Entity

DICOM Print

Application Entity

RIS

Application Entity

MPPS

Application Entity

Application Entity

Receives Images

& GSPS

Remote

Application Entity

Prints Film

Sheets

Remote

Application Entity

Provides Worklist

Items

Remote

Application Entity

Receives MPPS

Create / Update

Acquire Images

DICOM Standard

Interface

Figure 2.1-1: Functional Overview – Application Data Flow

2.1.2Functional Definitions of AE’s

2.1.2.1Functional Definition of DICOM Store Application Entity

The DICOM Store Application Entity sends images and Presentation States to a remote AE (This can be a configured Archiving station, a diagnostic workstation …). It is associated with the local real-world activity “Send Images & GSPS”. If Storage Commitment is configured for the archive destination, the DICOM Store AE will request Storage Commitment and a job will only be marked as successful when the commitment is

Page 9
Image 9
AGFA HE/001132 manual Implementation Model, Application Data Flow Diagram