2

Chapter 2 Operating Your Frequency Counter

Using Power Correction

5Press the Enter key to select profile number 3.

Power Correction is enabled using profile number 3, and the measurement display returns. The power reading now includes an adjustment for the loss incurred at the measured frequency. The amount of the adjustment is derived from the loss and frequency values in the data points in the selected profile. A lower-case letter “c” is shown in the hundredths position of the power-measurement display to indicate that Power Correction is enabled.

 

Ch 2

 

Freq

 

dBm

 

Pwr

NOTE

Pressing the Enter key when the number of a power-correction profile

 

(1-9) is displayed selects that profile, enables Power Correction, and exits

 

the Menu. If you intend to enter data in the currently displayed profile,

 

press the right-arrow key instead of the Enter key to select the

 

power-correction profile without exiting the Menu.

You can also select a power-correction profile by pressing the right- or left-arrow key (instead of the Enter key). When you press either arrow key, you do not exit the Menu. As the next example shows, you should select a profile with the right-arrow key when you intend to enter or change the loss and/or frequency values in the selected profile. You should select the power-correction profile with the left-arrow key if you are done working with the power-correction settings, but you want to change settings for other functions in the Menu.

2-34

Operating Guide

Page 88
Image 88
Agilent Technologies 53150A, 53152A, 53151A manual Press the Enter key to select profile number

53151A, 53150A, 53152A specifications

Agilent Technologies, renowned for its cutting-edge electronic measurement equipment, produced a range of high-performance frequency counters, among which the 53150A, 53151A, and 53152A models stand out. These versatile instruments are designed to cater to various measurement applications in telecommunications, aerospace, and research and development.

The Agilent 53150A is a high-performance frequency counter that operates on a wide frequency range, capable of measuring frequencies up to 2.7 GHz. This model features a 10 Hz to 2.7 GHz measurement capability with a time interval resolution of 100 ps, making it ideal for accurately capturing fast signals. Additionally, it offers a built-in statistical analysis feature that enables users to perform precise measurements, minimizing uncertainty in data collection.

Equally impressive, the Agilent 53151A enhances capabilities further by introducing advanced measurement functions. This model supports frequency and time interval measurements up to 3.5 GHz and includes an additional mode for measuring CW frequency and period. The enhanced resolution of 50 ps allows users to capture even finer variations in measured signals. The 53151A also features a user-friendly graphical display, simplifying data visualization and interpretation.

The Agilent 53152A pushes performance to new heights with frequency measurements extending up to 7 GHz. This model incorporates a high-speed external timebase for increased accuracy and uses advanced signal processing technology to ensure reliable measurements, even in noisy environments. One of the standout features of the 53152A is its capability to interface with a variety of devices, enabling remote measurements and integration into automated testing environments.

All three models employ state-of-the-art technology and boast characteristics that enhance their usability. They feature multi-channel capability, allowing simultaneous measurements, which is critical for complex applications. Their robust design and compact form factor make them suitable for both laboratory and field use, ensuring versatility in different working environments.

In summary, Agilent Technologies’ 53150A, 53151A, and 53152A frequency counters combine exceptional measurement accuracy, a wide frequency range, and advanced functionalities tailored for professionals across various scientific and engineering disciplines. Whether measuring signal frequency, time intervals, or conducting statistical analyses, these models are engineered to meet the demanding requirements of today’s high-tech world.