Index

Index

Operating the Counter from a DC Power Source, C-3

Operating the Counter from the Batteries, C-2

Operation

acknowledging messages, 2-9 changing states, 2-7 displaying the Menu, 1-12 function selection keys, 2-10 measuring frequency, 1-17,2-12 measuring power, 1-22 measuring relative frequency, 2-20 measuring relative power, 1-24,2-26 measuring relative frequency, 1-19 navigating in the Menu, 1-12 navigating in the menu and

changing settings, 2-41 numeric entry, 2-6 offsetting a frequency

measurement, 1-20,2-21 offsetting a power measurement, 1-24,

2-27

operating the Counter from the batteries, C-2

other function selection keys, 2-10 selecting the input channel, 1-16 selecting the unit of measurement

for power, 1-23

sequencing through the Menu, 2-5 setting the measurement rate, 1-32,

2-16

setting the number of averages, 2-17 setting the resolution, 2-14 setting the resolution and the

measurement rate, 2-14 Turning the Counter On, 1-10 using Power Correction, 2-30 using the Clear and Reset/Local

keys, 2-9

using the Menu, 1-12,2-39 using the selection keys, 2-5

Operation Hours, 1-14,2-42 Operation

measuring power, 2-24 Option Codes, 2-43 option codes, 1-14,2-42 optional Oven Timebase, 2-4,2-42 Options, xiii

Battery, 1-3 Hardware, xiii

Oven Timebase, 2-4,2-42Support, xiii

OPTNS, 2-40

Other Function Selection Keys, 2-10 Oven Timebase, 2-4,2-42

P

peaking, 2-24 percentage, 2-24,2-26 Planar Crown, 1-18 Power Correction

cable impedance, 2-30 data points, 2-30,2-33 disabling, 2-33 enabling, 2-33 frequency, 2-33 frequency value, 2-30 GZ, 2-37 interpolation, 2-30 LOSS, 2-36

loss, 2-33

loss value, 2-30 lower-case letter "c", 2-34 profiles, 2-30

PWR CORR > OFF, 2-33 selecting a correction profile, 2-33

Power Correction Example Selecting a Correction Profile, 2-33

Power Correction examples, 2-32 Power Correction function, 2-30 power difference, 2-26

power loss, 2-30

Power measurement, 1-5 power measurement, 2-24

Power Measurement Example, 2-24 Power Measurement Units (dBm/W

key), 2-45

Index-6

Operating Guide

Page 134
Image 134
Agilent Technologies 53151A, 53152A, 53150A manual Index-6 Operating Guide

53151A, 53150A, 53152A specifications

Agilent Technologies, renowned for its cutting-edge electronic measurement equipment, produced a range of high-performance frequency counters, among which the 53150A, 53151A, and 53152A models stand out. These versatile instruments are designed to cater to various measurement applications in telecommunications, aerospace, and research and development.

The Agilent 53150A is a high-performance frequency counter that operates on a wide frequency range, capable of measuring frequencies up to 2.7 GHz. This model features a 10 Hz to 2.7 GHz measurement capability with a time interval resolution of 100 ps, making it ideal for accurately capturing fast signals. Additionally, it offers a built-in statistical analysis feature that enables users to perform precise measurements, minimizing uncertainty in data collection.

Equally impressive, the Agilent 53151A enhances capabilities further by introducing advanced measurement functions. This model supports frequency and time interval measurements up to 3.5 GHz and includes an additional mode for measuring CW frequency and period. The enhanced resolution of 50 ps allows users to capture even finer variations in measured signals. The 53151A also features a user-friendly graphical display, simplifying data visualization and interpretation.

The Agilent 53152A pushes performance to new heights with frequency measurements extending up to 7 GHz. This model incorporates a high-speed external timebase for increased accuracy and uses advanced signal processing technology to ensure reliable measurements, even in noisy environments. One of the standout features of the 53152A is its capability to interface with a variety of devices, enabling remote measurements and integration into automated testing environments.

All three models employ state-of-the-art technology and boast characteristics that enhance their usability. They feature multi-channel capability, allowing simultaneous measurements, which is critical for complex applications. Their robust design and compact form factor make them suitable for both laboratory and field use, ensuring versatility in different working environments.

In summary, Agilent Technologies’ 53150A, 53151A, and 53152A frequency counters combine exceptional measurement accuracy, a wide frequency range, and advanced functionalities tailored for professionals across various scientific and engineering disciplines. Whether measuring signal frequency, time intervals, or conducting statistical analyses, these models are engineered to meet the demanding requirements of today’s high-tech world.