Table 4-2. Signal-Name Descriptions

Mnemonic

 

Function

 

Sheet 1

Sheet 2

Sheet 3

 

 

POWER BOARD

 

 

 

ACLR*

 

Analog circuits clear (D)

 

1A, 7B

 

 

 

 

 

 

BO*

 

Brown out input disable (D)

 

1A, 2B, 8B

 

 

+BUS

 

+ input binding post

 

 

4A

 

- BUS

 

- input binding post

 

 

4A

 

CC_PROG

 

Programming voltage for CC mode (A)

8C, 4C

 

 

CR*

 

CR_mode low range select (D)

 

8B

 

 

CV_PROG

 

Programming voltage for CV mode (A)

8D

 

 

E2

 

Electrical connection

 

8A, 6B

 

 

E8

 

Electrical connection

 

6A, 7D

 

 

E11

 

Electrical connection

 

5A, 8D

 

 

IMON*

 

Input-current monitor signal (A)

 

8B

7A

 

+IN

 

+input (A)

 

8A,7A,6D,l

4A

 

 

 

 

 

D,lC

4A

 

- IN

 

- input (A)

 

8A, 7A, 1D

 

+ IN Local

 

Same as + input (A)

 

1D

4A

 

+ OP

 

Overpower comparator input (A) (low = OP)

3A, 8A

 

 

- OP

 

Overpower comparator input (A) (high = OP)

4A, 8A

 

 

OP*

 

Overpower status (D)

 

8A

 

 

+OV

 

Overvoltage comparator input (A) (low = OV)

4D, 8B

 

 

OV*

 

Overvoltage status (D)

 

8B

 

 

PROG

 

Programming input to power circuits (A)

5D, 1C, 7B

8D

 

 

 

Overvoltage reference (A)

 

8B

 

 

RNG

 

CC-mode range select (D)

 

8C

 

 

R268-6

 

Resistor pin number

 

4B, 5D

 

 

R268-8

 

Resistor pin number

 

4B, 5D

 

 

R267-2

 

Resistor pin number

 

4C, 8D

 

 

R267-3

 

Resistor pin number

 

4C, 8C

 

 

R267-10

 

Resistor pin number

 

4C, 6B

 

 

+S

 

Remote + sense (A) (from rear-panel +S)

1D

 

 

- S

 

Remote - sense (A) (from rear-panel - S)

1D

 

 

SPCLR*

 

Secondary-circuit power-on clear (D)

1B

 

 

TEMP1

 

Power-board temperature (A)

 

1B

8A

 

TURNON

 

Power-on input disable (D)

 

8C

 

UNREG

 

Input to unregulated-input comparator (A)

8C, 4C

2C

 

UNREG*

 

Unregulated-input status (D)

 

8A

 

 

VMON*

 

Input-voltage monitor signal (A)

 

8D

 

 

VOFF

 

Voltage off

 

5D

2B

 

+12V_REF

 

Reference for overvoltage circuit (A)

1C

 

 

(A) = analog signal

 

(D) = digital signal

8C = signal origin

 

 

34