Agilent Technologies 668xA Output Subsystem, Outpprotcle Outpprotdel, 0 or, Outputprotdelay Max

Models: 668xA 669xA 667xA 664xA 665xA

1 70
Download 70 pages 51.66 Kb
Page 39
Image 39
Output Subsystem

Output Subsystem

This subsystem controls the power supply's voltage and current outputs and an optional output relay.

Do not install or program the Agilent Relay Accessories if the power supply maximum output current rating (see Table 3-1) exceeds the contact ratings of the relay.

OUTP

This command enables or disables the power supply output. The state of a disabled output is a condition of zero output voltage and a model-dependent minimum source current (see Table 3-1). The query form returns the output state.

Commandd Syntax

OUTPut[:STATe] <bool>

Parameters

0 OFF 1 ON

Suffix

(None)

 

*RST Value

0

 

Examples

OUTP 1

OUTPUT:STATE ON

Query Syntax

OUTPut(:STATe]?

Returned Parameters

<NR1>

0 or 1

Related Commands

*RST

*RCL *SAV

OUTP:PROT:CLE

OUTP:PROT:DEL

OUTP:PROT:CLE Clears any OV (overvoltage), OC (overcurrent, unless set via external voltage control),OT (overtemperature), or RI (remote inhibit) protection features. After this command, the output is restored to the state it was in before the protection feature occurred.

OUTP:PROT:DEL Sets the time between the programming of an output change that produces a CV, CC, or UNREG condition and the recording of that condition by the Status Operation Condition register. The delay prevents the momentary changes in power supply status that can occur during reprogramming from being registered as events by the status subsystem. Since the delay applies to CC status, it also delays the OCP (overcurrent protection) feature. The OVP (overvoltage protection) feature is not affected by this delay.

Examples

OUTP:PROT:CLE OUTPUT:PROTECTION:CLEAR

 

OUTPUT:PROTECTION:DELAY 75E-1

 

OUTP:PROT:DEL MIN

OUTPUT:PROT:DELAY MAX

Query Syntax

OUTP:PROT:CLE

(None)

 

 

OUTPut:PROTection:DELay?

OUTPut:PROTection:DELay? MIN

 

OUTPut:PROTection:DELay? MAX

Returned Parameters

<NR3> OUTP:PROT:DEL? returns value of programmed delay.

 

OUTP:PROT:DEL? MIN and OUTP:PROT:DEL? MAX return

 

the minimum and maximum programmable delays.

Related Commands

OUTP:PROT:CLE

(None)

 

 

OUTP:PROT:DEL

*RST

*RCL *SAV

Language Dictionary 39