Upgrading systems

Upgrading systems

Figure 8 shows the different 8510 systems and their components. This figure is an excellent guide when upgrading systems.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85106D

 

 

 

OR

Q-band

 

85106D #001

 

 

 

OR

Q-band

 

 

 

33 to 110 GHz

 

 

 

 

 

 

0.045 to 110 GHz

 

+

 

 

Waveguide

 

8510C

 

+ OR

U-band

 

8510C

 

OR

U-band

 

 

 

 

 

 

 

 

systems

 

 

 

 

 

85105A #050

 

 

 

 

 

85105A

 

 

 

 

 

V-band

 

8517B

 

 

 

OR

V-band

 

 

 

83621B

 

 

 

OR

 

 

 

83621B

 

 

 

 

 

 

 

83621B

 

 

 

 

 

W-band

 

83651B

 

 

 

 

W-band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-sweep

 

8510E

 

 

 

 

8510SX

 

85107B

 

 

 

8510XF

 

 

0.045 to 20 GHz

 

 

0.045 to 26.5 GHz

 

0.045 to 50 GHz

 

 

0.045 to 110 GHz

 

high

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8510C

 

 

8510C

 

 

 

 

8510C

 

8510C

 

 

 

 

performance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MM-wave subsystem

 

 

 

 

 

 

 

 

8515A

 

8517B

 

 

 

systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

83651B

 

 

83621B

 

 

 

 

83631B

 

83651B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

83621B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85108L

 

 

 

85108A*

 

 

 

85108A (50 GHz)

 

Pulsed-RF

 

0.045 to 2 GHz

 

 

 

2 to 20 GHz

 

 

 

 

2 to 50 GHz

 

or CW

 

8510C

 

 

 

 

 

8510C

 

 

 

 

 

8510C

 

systems

 

85110L

 

 

 

85110A

 

 

 

85110A (50 GHz)

 

 

83620B #H80

 

 

 

83622B

 

 

 

 

 

83650B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

83620B #H80

 

 

 

83623L

 

 

 

 

 

83621B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* 85108A also available in frequency range of 45 MHz to 20 GHz

Figure 8. 8510 family of system solutions

To upgrade from one system to another, simply order the pieces that are needed in the new system that are currently not in the existing system, an example is shown in Figure 9. Complete waveguide S-parameter systems require two test set modules for each band.1 Necessary accessories such as calibration kits, verification kits, test port cables or adapters2 must be ordered. See pages 17 through 19 for more information.

1.The following test set modules are available. Two test set modules must be ordered for complete waveguide S-parameter test set operation for each waveguide band:

Q85104A test set module (33 GHz to 50 GHz)

U85104A test set module (40 GHz to 60 GHz)

V85104A test set module (50 GHz to 75 GHz)

W85104A test set module (75 GHz to 110 GHz)

2.Please refer to the RF & Microwave Test Accessories Catalog (literature number 5964-9527E) on detailed information on available adapters.

12

Page 12
Image 12
Agilent Technologies 85107B, 8510XF manual + Or, Upgrading systems, 8510 family of system solutions