AM Receivers
146
AM Squelch Sensitivity Measurement
Description

This procedure is used to measure an AM Receiver’s critical squelch

and maximum squelch sensitivity. For critical squelch, the receiver is

just squelched with minimum modulated input at the Receiver’ s

antenna, then the input is increased until the squelch is opened.

Maximum squelch is the amount of modulated signal required to open

the squelch when the control is set to maximum. Minimum and

maximum squelch hysteresis is also measured and calculated.