Measurement Procedure:
1Connect the Transmitter as shown.
CAUTION: The RF present at the Test Set RF IN/O UT con nector mus t not exceed 60W
continuous (or 100 Watts for 10 sec/minute).
On the Test Set:
2Press the PRESET key.
Using the knob and the data entry keys:
3Select the AF ANL screen.
4Set Filter 1 to <20 Hz HPF setting.
5Set Filter 2 to 300 Hz LPF setting.
6Set Settling to Slow setting.
7Select the DECODER screen.
8Set Mode to CDCSS.
9Set Standard to CDCSS.
10 Set Input Level to 0.95 kHz.
11 Set Arm Meas to Cont.
On the Radio:
12 Key the Transmitter and keep keyed until the remaining steps are complet-
ed.
Data rate, binary data (bin), and the Octal Code(s) are displayed on the
Test Set as shown.
Test Set Options Required Decoder Option