Aiphone 0207 AIC operation manual Security Guard Station Wall-mounting

Models: 0207 AIC

1 47
Download 47 pages 63.87 Kb
Page 15
Image 15

3-7

1

2

[1]

[2]

3

45

 

 

1

 

2

 

 

4

 

 

 

3

 

 

5

 

 

7

 

 

 

 

6

 

8

 

 

 

 

 

 

 

9

 

 

0

 

 

 

 

Security Guard Station (Desk-top Mounting Using GFW-S Stand)

[1]Screws included with GFW-S (x4)

[2]Cable tie included with GFW-S

1. Separate the mounting bracket and the protective cover from the back of the unit.

2. Mount the mounting bracket to GFW-S as shown in the drawing.

3. Connect the wiring to the terminal block, inserting the wires into the slots in an orderly fashion.

Set the wiring in place with the cable tie to ensure that they are not pulled out.

4. Cover the terminal section with the protective cover.

5. Insert the mounting bracket latch and slide it upward until it locks.

3-8

[2] [1]

83.5mm (3-5/16")

1

A2

 

 

 

 

 

G4

BC

D3

OR

KL

7

M6

HI

J5

EF

 

 

 

 

QR

T8

NO

 

 

UV

9

 

 

 

 

 

0

XY

 

 

 

 

60mm (2-3/8")

[1]

[3]

[4]

Security Guard Station (Wall-mounting)

[1]1-gang box or round back box

[2]Mounting bracket

[3]Wiring slot

[4]Terminal block

1.Mount the mounting bracket on the 1-gang box.

2.Connect the wiring to the terminal block.

3.Mount the station unit to the mounting bracket.

Strip away the jacket of the cable and insert all wires into the

slots in an orderly fashion. Failure to do so could result in pinching that may damage the wiring.

NOTES: 1. To remove the terminal block, slide it to the left and pull it out.

2.To wire along the main unit surface, use a nipper to cut the section shown on the drawing.

Peel off protection film on display.

- 15 -

Page 15
Image 15
Aiphone 0207 AIC operation manual Security Guard Station Wall-mounting