Bus Control Unit and Power Supply
[1]Din rail (W-DIN11)
[2]Screw hole
[3]POWER switch
[4]Power On LED (green)
[5]Lock release lever
[6]Wall mounting screws (x2)
1.Mount GH-BC and GH-VBC to the Din rail. Click unit into place.
∗To remove GH-BC and GH-VBC, pull the lock release lever down.
∗If there is a problem with the system, check the power supply wiring. Turn off the GH-BC and GH-VBC power switch and then turn the switch back on after four seconds. This will reset the entire system.
2.Mount GH-BC and GH-VBC directly to the wall surface.
3.Mount GH-4Z to the Din rail.
∗To remove GH-4Z, pull the lock release lever down.
4. Mount GH-4Z directly to the wall surface.
5. Mount GH-BCX/A and GH-VBX to the Din rail. To remove
GH-BCX/A and GH-VBX, pull the lock release lever down. 1. GH-BCX/A and GH-VBX cannot be mounted directly to
the wall surface.
2. The length of the connecting cable between the GH-BCX/A and GH-VBX is 40 cm (15-3/4"). Therefore, mount the GH- BCX/A and GH-VBX adjacent to each other.
6. Power supply PS-2410LC, PS-2410LD, PS-2410DIN Red: +
Black: -