Nederlands Español Deutsch Français English
OPERATIONS
A.Unlocking of user code
When the registered user code has been input using the keypad (between 4 and 6 digits), the LED indicator (group 1: orange, group 2: green) lights up, the buzzer sounds,
and the electric door strike is unlocked.
ex.): group 1 | group 2 |
1006 | 04B2 |
Orange LED lights up (during relay1 operation) | Green LED lights up (during relay2 operation) |
Beep | Beep |
•The time interval during which the button must be pressed is approximately 10 seconds. If the time interval exceeds approximately 10 seconds, the input value will be cleared.
•If you make a mistake when inputting the user code, input the user code again.
•When the "Lockout" function has been set, the release function is locked and the input operation is disabled for the specified time (10 ~ 99 seconds) if invalid codes are input a set number of times (10 ~ 99 times). (Reference: "Lockout".) During this time, the key illumination will blink 4 times, the LED (orange) indicator will blink for the set deactivation time, and the buzzer will sound for approximately 3 seconds.
B.
When the
The key illumination lights up when the timer is activated by performing the setting.
C.Unlocking using the request to exit/entry button
When leaving the premises, you can activate the electric door strike by pressing the request to exit/entry button connected to the unit. Pressing request to exit/entry button 1 releases relay 1, and pressing request to exit/ entry button 2 releases relay 2.
•When the door is unlocked using the request to exit/ entry button, the LED will not light up and the buzzer will not sound.
TECHNICAL PRECAUTIONS
•Operating temperature: Between
•Cleaning: Clean the unit with a soft cloth dampened with a neutral household cleanser. Do not use any abrasive cleanser or cloths.
•The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.
•Press and release the ,,, and keys simultaneously when this unit does not work.
)The LEDs (orange and green) will blink and the buzzer will sound, and then resetting will take place. (The settings do not return to their default values.)
•If resetting does not work, contact the service technician who installed the unit.
SPECIFICATIONS
•Power supply: 12 ~ 24V AC 12 ~ 24V DC
•Power consumption: DC: Max. 70mA AC: Max. 100mA
•Dimensions:
H
H
H
•Weight:
•IP: IP54
•Number of relay circuits: 2
•Relay contact: N/O, N/C
•Relay contact capacity: 24V DC, 3A (resistive load) 1A (inductive load)
24V AC, 3A (resistive load)
1A (inductive load)
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to
use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result.
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
9