■Connections (IS-DV and IS-DVF)
Electric door strike *1
10m (33')
AC transformer
PT
10m (33')
10m (33')
*Connect to the electric door strike according to its specifications.
NC COM NO
CAT5e/6 |
|
|
|
|
|
| |
D | D1 | D4 |
|
300m (980') | (Select one port.) | Central control unit | |
|
|
|
or
CAT5e/6
|
|
| |
| D1 | D8 |
|
300m (980') | (Select one port.) | ||
|
|
|
Option | Inlet | * | The terminals are inside the terminal |
wires |
|
| cover. After connecting, route the |
|
|
| |
|
|
| wires through the wiring paths, then |
|
|
| close the cover. |
|
| * | Be sure to route the CAT5e/6 cable |
|
|
| and option wires through inlet. |
|
| * | When closing the terminal cover, |
CAT5e/6 cable | Terminal cover | close it until it clicks. | |
|
*1: Output specifications
Output method | N/O or N/C dry closure contact |
|
|
Voltage between | 24V AC, 0.5A (resistive load) |
terminals | 24V DC, 0.5A (resistive load) |
| Minimum overload (AC/DC): |
| 100mV, 0.1mA |
NOTES:
•Do not use the unoccupied terminals and ports for other purposes.
•In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
•For connecting other manufacture’s products, refer to the instruction manuals for those products.
•The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
22