Connections (IS-DV and IS-DVF)

Electric door strike *1

φ0.65-1.2mm (22-16 AWG)

10m (33')

AC transformer

PT

φ0.65-1.2mm (22-16 AWG)

10m (33')

φ0.65-1.2mm (22-16 AWG)

10m (33')

*Connect to the electric door strike according to its specifications.

NC COM NO

CAT5e/6

 

 

 

(non-shielded)

 

 

 

D

D1

D4

 

300m (980')

(Select one port.)

Central control unit

 

 

 

(IS-CCU)

or

CAT5e/6

(non-shielded)

 

 

 

 

D1

D8

 

300m (980')

(Select one port.)

Add-on control unit

 

 

 

(IS-SCU)

Option

Inlet

*

The terminals are inside the terminal

wires

 

 

cover. After connecting, route the

 

 

 

 

 

 

wires through the wiring paths, then

 

 

 

close the cover.

 

 

*

Be sure to route the CAT5e/6 cable

 

 

 

and option wires through inlet.

 

 

*

When closing the terminal cover,

CAT5e/6 cable

Terminal cover

close it until it clicks.

 

*1: Output specifications

Output method

N/O or N/C dry closure contact

 

 

Voltage between

24V AC, 0.5A (resistive load)

terminals

24V DC, 0.5A (resistive load)

 

Minimum overload (AC/DC):

 

100mV, 0.1mA

NOTES:

Do not use the unoccupied terminals and ports for other purposes.

In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.

For connecting other manufacture’s products, refer to the instruction manuals for those products.

The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.

22

Page 22
Image 22
Aiphone installation manual Connections IS-DV and IS-DVF, Close it until it clicks