Connections

Contact output *1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Electric door strike,

Contact input *2

 

 

 

 

 

 

 

 

 

 

 

 

strobe light, etc.)

(Sensor, etc.)

 

External speaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(more than 8Ω 3W)

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2C

 

 

2C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2C

 

 

 

 

 

 

 

 

 

 

 

φ0.65-1.2mm

 

φ0.65-1.2mm

 

 

 

 

 

 

 

 

 

 

 

 

 

(22-16 AWG)

 

(22-16 AWG)

 

φ0.65-1.2mm

 

 

 

 

 

 

 

 

 

 

15m (50')

 

15m (50')

 

(22-16 AWG)

 

 

 

 

 

 

 

 

 

 

 

 

 

15m (50')

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SP

 

PAGING

 

 

 

 

 

 

 

 

 

 

 

SP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

CONTACT

 

 

 

 

 

 

 

 

 

 

 

SE

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

CONTACT

 

 

 

 

 

 

 

 

 

 

 

COM

 

OUT

NP: Non-polarized

P: Polarized

*1: Output specifications

Output method

N/O dry closure contact

 

 

Voltage between

24V AC, 0.5A (resistive load)

terminals

24V DC, 0.5A (resistive load)

 

Minimum overload (AC/DC):

 

100mV, 0.1mA

CAT5e/6

 

 

 

(non-shielded)

 

 

 

 

D1

D4

 

150m (490')

(Select one port.)

Central control unit

 

 

 

(IS-CCU)

 

 

or

 

CAT5e/6

 

 

 

(non-shielded)

 

 

 

 

D1

D8

 

150m (490')

(Select one port.)

Add-on control unit

 

(IS-SCU)

or

CAT5e/6

(non-shielded)

C1 C30

150m (490')

(Select one port.)

Room sub control unit

 

 

(IS-RCU)

*2: Input specifications

Input method

N/O or N/C dry closure contact (start

 

signal only detection method)

Detection confirmation

100 ms or more

time

 

Contact resistance

During N/O dry closure: Less than 700 Ω

 

During N/C dry closure: At least 4 k Ω

Terminal short current

Less than 10 mA

Voltage between

Less than 5 V DC (when open between

terminals

terminals)

NOTES:

Do not use the unoccupied terminals and ports for other purposes.

In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.

For connecting other manufacture’s products, refer to the instruction manuals for those products.

The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.

25

Page 25
Image 25
Aiphone IS installation manual C1 C30